Synapse
⌘+K
Synapse
PulseExploreClubsResearchersJournals
Instagram
HomeClubsExplore
September 1, 1988Journal of Cardiac Surgery

Long-Term Evaluation of the Ionescu-Shiley Pericardial Xenograft Bioprosthesis in the Aortic Position

View Full Paper
Ask AI
Bookmark
Share

Key result

Aortic valve replacement with the Ionescu-Shiley pericardial valve demonstrated an expected 10.5-year actuarial survival rate of 82% and a 77.5% freedom from primary tissue failure.

Population

241 patients undergoing aortic valve replacement, average age 50.8 years, 130 males and 11 females. 121 had…

Design

Cohort

Follow-up

mean 5.16 years, maximum 10.5 years

Authors

JRJosé M. RevueltaUniversidad de CantabriaJCJ. CagigasUniversidad de CantabriaMLM A LequericaUniversidad de Cantabria

Discussion

Loading...

Member takes

Implication

Long-term cohort data support pericardial AVR durability; leaves open comparisons with contemporary bioprostheses.

Study Design

Type

Cohort (n=241)

Structured PICO

P
Population
241 patients (mean age 50.8 years) undergoing aortic valve replacement with the Ionescu-Shiley pericardial valve, followed for a mean of 5.16 years.
E
Exposure
Ionescu-Shiley pericardial xenograft bioprosthesis in the aortic position
O
Outcome
Actuarial survival rate and freedom from valve-related complications (thromboembolism, structural valve deterioration, reoperation) at up to 10.5 yearshard clinical

Long-term evaluation of the Ionescu-Shiley pericardial xenograft in the aortic position demonstrated an 82% survival rate at 10.5 years, though structural valve deterioration and reoperation remained notable clinical events.

Cite This Study

Revuelta et al. (1988) conducted a cohort in Aortic valve disease requiring replacement (n=241). Ionescu-Shiley pericardial valve was evaluated on 10.5 year actuarial survival. Aortic valve replacement with the Ionescu-Shiley pericardial valve demonstrated an expected 10.5-year actuarial survival rate of 82% and a 77.5% freedom from primary tissue failure.

synapsesocial.com/papers/6a9fa0b01cf0e01ec7bab372https://doi.org/10.1111/jocs.1988.3.3s.391

Topics

Valvular heart disease
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Performance of the lonescu-Shiley Pericardial Valve in the Aortic Position: 100 Months Clinical Experience1986 · 16 citations
  2. 2Multiple valve replacement with pericardial xenograft. Clinical and haemodynamic study.1980 · 17 citations
  3. 3Long-term haemodynamic evaluation of aortic pericardial xenograft.1978 · 32 citations