August 1, 1986The Thoracic and Cardiovascular Surgeon

Performance of the lonescu-Shiley Pericardial Valve in the Aortic Position: 100 Months Clinical Experience

View Full Paper
Ask AI
Bookmark
Share

Key result

Aortic valve replacement with the Ionescu-Shiley pericardial valve resulted in an expected 100-month survival rate of 82.8% and a 94.4% freedom from thromboembolic episodes.

Why the study?

What are the long-term clinical outcomes and survival rates of patients undergoing aortic valve replacement with the Ionescu-Shiley pericardial valve?

Population

239 patients undergoing aortic valve replacement, average age 50.6 years, 128 males and 111 females. 112 had…

Design

Cohort

Follow-up

mean 44.9 months (up to 100 months)

Authors

CDCarlos E. DuránUniversity Medical Center Utrecht

Discussion

Loading...

Member takes

Implication

Supports acceptable long-term performance of pericardial AVR; leaves open effects of concomitant procedures.

Study Design

Type

Cohort (n=239)

Structured PICO

What are the long-term clinical outcomes and survival rates of patients undergoing aortic valve replacement with the Ionescu-Shiley pericardial valve?

P
Population
239 patients (mean age 50.6 years) who underwent aortic valve replacement with the Ionescu-Shiley pericardial valve, followed for a mean of 44.9 months.
E
Exposure
Aortic valve replacement with the Ionescu-Shiley pericardial valve
O
Outcome
Survival rate at 100 monthshard clinical

The Ionescu-Shiley pericardial valve demonstrated satisfactory long-term performance in the aortic position, with higher complication rates observed in patients undergoing concomitant cardiac surgery.

Cite This Study

Carlos E. Durán (1986) conducted a cohort in Aortic valve disease requiring replacement (n=239). Ionescu-Shiley pericardial valve was evaluated on 100 months survival rate. Aortic valve replacement with the Ionescu-Shiley pericardial valve resulted in an expected 100-month survival rate of 82.8% and a 94.4% freedom from thromboembolic episodes.

synapsesocial.com/papers/6a9fa0be3a35f4a2c890d5c2https://doi.org/10.1055/s-2007-1020421

Topics

Valvular heart disease
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Long-Term Evaluation of the Ionescu-Shiley Pericardial Xenograft Bioprosthesis in the Aortic Position1988 · 5 citations
  2. 2A ten-year study of the Ionescu-Shiley low-profile bioprosthetic heart valve1994 · 12 citations
  3. 3Durability of the pericardial valve1984 · 12 citations
  4. 4The Carpentier-Edwards pericardial aortic valve: intermediate results in 420 patients1994 · 17 citations
  5. 5Pericardial valves in small aortic annuli: ten years' results1996 · 7 citations