Key result
Aortic valve replacement with the Ionescu-Shiley pericardial valve resulted in an expected 100-month survival rate of 82.8% and a 94.4% freedom from thromboembolic episodes.
Why the study?
What are the long-term clinical outcomes and survival rates of patients undergoing aortic valve replacement with the Ionescu-Shiley pericardial valve?
Cohort (n=239)
What are the long-term clinical outcomes and survival rates of patients undergoing aortic valve replacement with the Ionescu-Shiley pericardial valve?
The Ionescu-Shiley pericardial valve demonstrated satisfactory long-term performance in the aortic position, with higher complication rates observed in patients undergoing concomitant cardiac surgery.
Answers are grounded in this paper and cite their sources.
Supports acceptable long-term performance of pericardial AVR; leaves open effects of concomitant procedures.
From August 1977 through August 1984, 239 patients underwent aortic valve replacement (AVR) with the Ionescu-Shiley pericardial valve. Isolated AVR was performed in 112 patients and associated cardiac surgery in 127 patients (53.1%). One hundred twenty-eight patients were males and 111 females, with an average age of 50.6 years (range 15 to 78 years). There were 24 hospital deaths (10%) and 15 late deaths (8.9%). The expected 100 months survival rate was 82.8 +/- 5.5 (91.3 +/- 5.6% for isolated AVR, and 75 +/- 7.8% for associated AVR). All patients were postoperatively studied until December 1985. The cumulative duration of follow-up was 894.08 patient-years, with a mean follow-up of 44.9 months per patient. There were 10 thromboembolic episodes in this series (3 peripheral and 7 central), with a linearized incidence of 1.1% per patient-year. The actuarial projection of freedom from thromboembolic episodes at 100 months follow-up was 94.4 +/- 3.4% (96.9 +/- 2.2% for isolated AVR, and 92.6 +/- 3.9% for associated AVR). Twenty-five patients required reoperation (2.79% per patient-year): 6 for infective endocarditis, 3 for paravalvular leak, one for valve thrombosis, 3 for another valve explantation, and 12 for primary tissue failure (1.3% per patient-year). In conclusion, the Ionescu-Shiley valve has a satisfactory performance in the aortic position at long-term follow-up. In our experience, the higher rate of postoperative complications occurred among patients with concomitant cardiac surgery, so not necessarily related to this pericardial valve.
No takes yet. Share an insight, caveat, or question.
Carlos E. Durán (1986) conducted a cohort in Aortic valve disease requiring replacement (n=239). Ionescu-Shiley pericardial valve was evaluated on 100 months survival rate. Aortic valve replacement with the Ionescu-Shiley pericardial valve resulted in an expected 100-month survival rate of 82.8% and a 94.4% freedom from thromboembolic episodes.