Key result
Harmonizing gluten ELISA assays using a common calibrator reduced between-assay variability, but bias caused by differences in assay selectivity remained unaffected.
Harmonizing gluten ELISA measurements using reference materials alone is insufficient due to differences in assay selectivity, requiring consensus on robust markers.
Answers are grounded in this paper and cite their sources.
ELISA variability undermines reliable EU gluten-free enforcement; leaves open need for consensus markers beyond reference materials.
Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required.
No takes yet. Share an insight, caveat, or question.
Rzychon et al. (2017) studied Gluten measurement. Harmonization of gluten ELISA assays (common extraction procedure, common calibrator) vs. Routine ELISA methods was evaluated on Comparability of measurements and between-assay variability. Harmonizing gluten ELISA assays using a common calibrator reduced between-assay variability, but bias caused by differences in assay selectivity remained unaffected.
Synapse has enriched 10 related papers. Consider them for comparative context: