Key result
Transcatheter J-valve ViV implantation succeeds in 2 high-risk tricuspid degeneration patients without major adverse events.
Why the study?
Patients with tricuspid bioprosthetic structural valve degeneration often face high risk from redo cardiac surgery, leading to the use of the J-valve system for valve-in-valve implantation.
Is transcatheter valve-in-valve implantation with the J-valve system feasible and effective for treating tricuspid bioprosthetic structural valve degeneration in high-risk patients?
Case Report (n=2)
No
Is transcatheter valve-in-valve implantation with the J-valve system feasible and effective for treating tricuspid bioprosthetic structural valve degeneration in high-risk patients?
Transcatheter valve-in-valve implantation using the J-valve system appears feasible and effective for treating tricuspid bioprosthetic structural valve degeneration in high-risk patients.
May support use in select high-risk tricuspid cases; hypothesis-generating and requires larger prospective confirmation.
Background: Patients with tricuspid bioprosthetic structural valve degeneration (SVD) often present with right ventricular enlargement and severe dysfunction, which cause a higher risk for redo cardiac surgery. In 2019, our center innovated using the J-valve system for valve-in-valve (ViV) implantation to treat tricuspid bioprosthetic SVD. The purpose of this study was to summarize the clinical effect after 1-year follow-up. Case Description: From April 2019 to October 2019, two cases of tricuspid bioprosthetic dysfunction were treated with the J-valve system. Both patients were male, aged 46 and 67 years, respectively. The preoperative evaluation showed that the risk of conventional redo open heart surgery was high. The J-valve implantation was successful in both cases. One patient had slight valve displacement when the transporter was withdrawn during the operation, and a second J-valve was implanted in an ideal position. There was no death, no delayed valve displacement, and no readmission during the follow-up period of 12 months. In both cases, there was an absence of trace tricuspid regurgitation. After 6 months of anticoagulation with warfarin, the patients were converted to long-term aspirin treatment. Conclusions: The ViV technique with J-valve is feasible and effective in treating tricuspid bioprosthetic SVD in high-risk patients, avoiding cardiopulmonary bypass and conventional thoracotomy injury.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2024) conducted a case report in Tricuspid bioprosthetic structural valve degeneration (SVD) (n=2). J-valve system for valve-in-valve (ViV) implantation was evaluated on Clinical effect after 1-year follow-up (death, delayed valve displacement, readmission, and tricuspid regurgitation). Transcatheter valve-in-valve implantation using the J-valve system was successful in 2 high-risk patients with tricuspid bioprosthetic degeneration, with 0 deaths or readmissions at 12 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: