Key result
Novel percutaneous artificial bicuspid aortic and venous valves show successful insertion in animal models.
Why the study?
Is a new artificial bicuspid aortic and venous valve constructed from stents and porcine SIS feasible and functional for percutaneous insertion in animal models?
Is a new artificial bicuspid aortic and venous valve constructed from stents and porcine SIS feasible and functional for percutaneous insertion in animal models?
Answers are grounded in this paper and cite their sources.
This preclinical study demonstrates the initial experimental feasibility of a novel percutaneously inserted artificial bicuspid valve made of stents and porcine submucosa in animal models.
The purpose of this paper is to present in vitro and in vivo experimental evaluation of a new, artificial, bicuspid, aortic and venous valve. Valves were constructed from square stents with barbs covered by porcine small intestine submucosa (SIS). A valve 15 mm in diameter was tested in a flow model (2.5 l/min) with pressure measurement. A 100-ml rubber bag attached to a side arm of the flow model simulated heart ejection fraction. In acute (n=6) and short-term (n=3) experiments conducted in four swine and four dogs, valves ranging from 16-28 mm in diameter were placed into the ascending aorta through 10 F sheaths; three were placed subcoronary and six in a supracoronary position. Function and stability of the valves were studied with pressure measurements and aortograms. Three short-term animals were sacrificed for gross and histologic evaluation at one, two and four weeks respectively. In an acute experiment, venous valves with four barbs were placed into the IVC through an 8 F guiding catheter in three dogs. For longer-term testing, valves were placed into the IVCs and iliac veins of three young swine. The animals were followed up after two weeks with venograms, then were sacrificed for gross and histologic evaluation.
No takes yet. Share an insight, caveat, or question.
Pavčnik et al. (2000) studied this question. Artificial bicuspid aortic and venous valve was evaluated on Function and stability of the valves (pressure measurements, aortograms, venograms, gross and histologic evaluation). A new artificial bicuspid aortic and venous valve constructed from square stents covered by porcine small intestine submucosa was successfully inserted percutaneously and evaluated in animal models.
Synapse has enriched 10 related papers. Consider them for comparative context: