Key result
Elevated ECG, PCG, and radial artery risk score linked to ~285% higher HF risk.
Why the study?
Heart failure has high global prevalence and mortality, and screening methods still need improvement.
Does a risk score combining ECG, PCG, and radial artery features accurately screen for heart failure?
Cross-Sectional (n=813)
No
Does a risk score combining ECG, PCG, and radial artery features accurately screen for heart failure?
A novel risk score combining ECG, PCG, and radial artery features demonstrates good diagnostic performance for the early screening of heart failure.
Answers are grounded in this paper and cite their sources.
May support multimodal HF screening tools if validated; leaves open external validation and prospective trials before clinical use.
Heart failure has high prevalence and mortality all over the world, the screening of heart failure still needs improving. This study aimed to construct a risk score of early clinical detection for heart failure based on features associated with electrocardiogram (ECG), phonocardiogram (PCG), and radial artery. This study collected data of 813 participants from the First People's Hospital of Shangqiu city, between January 2023 and December 2023. All the samples were randomly divided into the training set and the testing set at a ratio of 7:3. Features selected through logistic regression and stepwise regression were included in the construction of the scoring system. The screening values of this scoring system for heart failure were verified in the testing set, with the odds ratio (OR), area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as their respective 95% confidence interval (CI) for evaluation. Totally 813 participants were included in this study. Participants with heart failure had higher scores than those without. The elevation of the score was associated with increased risk of heart failure in the training set (OR = 4.461, 95%CI: 3.209-6.200) and testing set (OR = 3.854, 95%CI: 2.364-6.281). The AUC of the risk score for heart failure was 0.802 (95%CI: 0.744-0.859) in the training set and 0.762 (95%CI: 0.669-0.855) in the testing set. The risk score had good screening value for heart failure, which might provide a valuable tool for early identification of patients with heart failure and offer timely interventions for these patients to improve their prognosis.
No takes yet. Share an insight, caveat, or question.
Chee et al. (2025) conducted a cross-sectional in Heart failure (n=813). Risk score based on electrocardiogram, phonocardiogram, and radial artery features vs. Lower risk score was evaluated on Diagnosis of heart failure (OR 3.854, 95% CI 2.364-6.281, p=<0.001). An elevated risk score combining electrocardiogram, phonocardiogram, and radial artery features was associated with an increased risk of heart failure in the testing set.