Key result
Measuring APC resistance without factor V-deficient plasma dilution detects thrombotic risks beyond factor V Leiden.
Why the study?
Does measurement of APC resistance without dilution in factor V-deficient plasma detect thrombotic risk factors other than Factor V Leiden?
Population
65 subjects in a blinded case-control study
Design
Case-control, blinded
Authors
Loading...
May detect additional thrombotic risks beyond FV Leiden; hypothesis-generating and should not yet change testing practice.
Case-Control (n=65)
Blinded
Does measurement of APC resistance without dilution in factor V-deficient plasma detect thrombotic risk factors other than Factor V Leiden?
Measurement of APC resistance without dilution in factor V-deficient plasma can identify potentially important thrombotic risk factors beyond Factor V Leiden.
Graf et al. (2003) conducted a case-control in Venous thromboembolism (n=65). Activated protein C (APC) resistance assay without dilution in factor V-deficient plasma vs. Assays with dilution in factor V-deficient plasma or RVV was evaluated on Detection of APC resistance. Measurement of APC resistance without dilution in factor V-deficient plasma identified 24 APC-resistant subjects, detecting thrombotic risk factors other than factor V Leiden.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: