Key result
Elevated myocardial digoxin linked to ~75% incidence of serious ventricular arrhythmias after cardiac surgery.
Why the study?
What is the relationship between serum and myocardial digoxin concentrations in patients undergoing cardiac surgery?
Observational (n=27)
What is the relationship between serum and myocardial digoxin concentrations in patients undergoing cardiac surgery?
Myocardial digoxin concentrations are approximately 70 times higher than serum concentrations, and elevated myocardial levels (>100 ng/g) may be associated with an increased risk of post-operative ventricular arrhythmias.
Answers are grounded in this paper and cite their sources.
High myocardial digoxin may raise post-operative arrhythmia risk; small cohort leaves open need for prospective tissue-level studies.
Summary: In an attempt to evaluate the serum digoxin concentration as a guide to digitalis treatment, serum and myocardial concentrations were measured in 27 patients undergoing cardiac surgery. Myocardial samples were taken from the right atrium immediately prior to institution of cardiopulmonary bypass; blood was taken in the previous 1–2 hours. Digoxin was extracted from the myocardial sample using a methanol/ water technique, which allowed a yield of 95%± 7%. Digoxin estimations were carried out using radioimmunoassay, with antibody raised in rabbits to a digoxinbovine serum albumin conjugate. No digoxin activity was found in the myocardium of six patients who were not being treated with the drug. In the 21 patients under treatment with digoxin, serum concentration averaged 1.2 ng/ml (range 0.64-2.3) and myocardial concentration averaged 76.5 ng/g (range 30–175). The ratio of myocardial to serum concentration averaged 70:1 (range 25:1 to 128:1) with standard deviation (SD) 28:1. The ratios of myocardial digoxin concentration to serum digoxin concentration exhibited a normal distribution in that 67% of the patients fell within ± 1 SD and 95% of the patients fell within ± 2 SD of the mean. Serious post-operative ventricular arrhythmias were noted in three of four patients with myocardial digoxin concentrations over 100ng/g but in only two of 23 patients with myocardial concentrations less than 100 ng/g.
No takes yet. Share an insight, caveat, or question.
Carroll et al. (1973) conducted an observational in Cardiac surgery (n=27). Myocardial digoxin concentration >100 ng/g vs. Myocardial digoxin concentration <100 ng/g was evaluated on Serious post-operative ventricular arrhythmias. Myocardial digoxin concentrations >100 ng/g were associated with serious post-operative ventricular arrhythmias in patients undergoing cardiac surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: