Key result
Real-time three-dimensional echocardiography indices of left ventricular mechanical dyssynchrony correlated moderately with tissue Doppler imaging (r=0.64-0.65, p<0.01).
Why the study?
Does real-time three-dimensional echocardiography accurately assess left ventricular systolic synchronicity compared to tissue Doppler imaging in patients with congestive heart failure?
Cross-Sectional (n=92)
Does real-time three-dimensional echocardiography accurately assess left ventricular systolic synchronicity compared to tissue Doppler imaging in patients with congestive heart failure?
Effect estimate: r = 0.64-0.65
p-value: p=< 0.01
Real-time three-dimensional echocardiography is a feasible and reliable method for quantifying left ventricular mechanical dyssynchrony in patients with congestive heart failure.
Supports 3D echo feasibility for LV dyssynchrony in HF; leaves open validation versus tissue Doppler before clinical adoption.
BACKGROUND: To investigate the clinical value of real-time three-dimensional echocardiography (RT-3DE) for assessing of left ventricular systolic synchronicity. METHODS: Thirty healthy volunteers and 62 patients with congestive heart failure (CHF) were enrolled. The SD of time to peak systolic motion (TDI-Ts12-SD) was measured with tissue Doppler imaging in 12 myocardial segments. The SD and maximal difference of the time to minimal systolic volume (Tmsv) between 16, 12, or 6 myocardial segments, expressed as a percentage of cardiac cycle duration, were measured with RT-3DE and labeled Tmsv16-SD%, Tmsv12-SD%, Tmsv6-SD%, Tmsv16-D%, Tmsv12-D%, and Tmsv6-D%, respectively. The Spearman coefficient and Kappa value were calculated, and Bland-Altman analysis was performed to investigate the correlation and agreement between the two methods. Tmsv values were compared with ejection fraction (EF). RESULTS: There was a moderately positive (p< 0.01) correlation between TDI-Ts12-SD and Tmsv16-SD%, Tmsv12-SD%, Tmsv16-D%, and Tmsv12-D% (r = 0.65, 0.64, and 0.65, respectively, with Kappa values of 0.66, 0.65, 0.72, and 0.74, respectively, p< 0.01). Tmsv16-SD%, Tmsv12-SD%, and Tmsv12-D% were significantly different between CHF patients with EF ≤ 35% and those with EF > 35%. CONCLUSIONS: RT-3DE can be used in patients with CHF to quantify left ventricular mechanical dyssynchrony. Tmsv12-SD% and Tmsv12-D% were the best indices of left ventricular systolic synchronicity in relation to the severity of CHF as evaluated from EF.
No takes yet. Share an insight, caveat, or question.
Li et al. (2012) conducted a cross-sectional in Congestive heart failure (n=92). Real-time three-dimensional echocardiography (RT-3DE) vs. Tissue Doppler imaging (TDI) was evaluated on Correlation between TDI-Ts12-SD and Tmsv indices (r = 0.64-0.65, p=< 0.01). Real-time three-dimensional echocardiography indices of left ventricular mechanical dyssynchrony correlated moderately with tissue Doppler imaging (r=0.64-0.65, p<0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: