Key result
Supra-annular and apical fixation yield trace paravalvular leak while subvalvular fixation worsens leakage and ischemia.
Why the study?
Do novel fixation strategies (supra-annular and subvalvular) improve stent performance and heart function compared to apical tether fixation in a porcine model of transcatheter mitral valve implantation?
Do novel fixation strategies (supra-annular and subvalvular) improve stent performance and heart function compared to apical tether fixation in a porcine model of transcatheter mitral valve implantation?
p-value: p=<0.001
In a porcine model, supra-annular fixation for transcatheter mitral valve implantation demonstrated good alignment and low paravalvular leakage, whereas subvalvular fixation was associated with moderate leakage and impaired cardiac function.
Animal findings should not guide clinical fixation choices; leaves open optimal transcatheter mitral valve strategies for human trials.
OBJECTIVES: Transcatheter mitral valved stent implantation provides an off-pump treatment option for mitral valve regurgitation, especially for secondary mitral valve regurgitation. The aim of this study was to evaluate novel fixation strategies: direct fixation (SUPRA) and subvalvular fixation (sub-VALV) to successfully implement alternative fixation methods at the mitral annulus and to reduce radial stent and apical tether forces. METHODS: Specific concepts were developed for the supra-annular hook-shaped fixation (SUPRA) and the subvalvular fixation (sub-VALV). These prototypes were compared with the sole apical tether fixation (AP) methods. Thirty-three pigs underwent mitral valved stent implantation accompanied by standardized transoesophageal echocardiographic and haemodynamic evaluation of heart function and the stent performance 1 h after implantation. Additionally, animals were followed up for 3 months. RESULTS: Secure deployment and correct positioning with low transvalvular gradients were achieved in all cases with mitral valved stent implantation. Nevertheless, 2 pigs died due to rhythm disturbances during dissection and pre-transcatheter mitral valve implantation. Paravalvular leakages were trace or less in prototypes with supra-annular fixation and sole apical fixation. In contrast, moderate paravalvular leakages were observed in the sub-VALV group (P < 0.001). In addition, the effect of a specific stent design on heart function was demonstrated: an increased rate of ischaemia and arrhythmia (P = 0.037) and a small left ventricular ejection fraction reduction (P < 0.05) were observed in the group with subvalvular fixation. In all but 1 case, gross evaluation demonstrated a good ingrowth of the valved stents of between 36% and 100% tissue coverage after a follow-up of 1 month or longer. CONCLUSIONS: The low degree of paravalvular leakages in the supra-annular and apical fixation groups and the normal longitudinal function highlight the good alignment of these new mitral valved stent designs within the native anatomy. The novel, hook-shaped, supra-annular fixation elements were well tolerated in the hearts resulting in excellent health of the animals at long-term follow-up times of up to 3 months.
No takes yet. Share an insight, caveat, or question.
Loger et al. (2018) studied Mitral valve regurgitation (n=33). Supra-annular and subvalvular fixation strategies vs. Sole apical tether fixation was evaluated on Paravalvular leakages and heart function (p=<0.001). Supra-annular and apical fixation strategies resulted in trace or less paravalvular leakages, whereas subvalvular fixation was associated with moderate leakages (P<0.001) and increased ischemia.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: