CO2 addition alters dog blood pH with a ~7 second half-time matching uncatalyzed hydration kinetics.
The measured half-time of pH changes in dog blood in vitro and in vivo aligns with mathematical predictions based on uncatalyzed CO2 hydration kinetics.
Answers are grounded in this paper and cite their sources.
Supports uncatalyzed CO2 hydration model in canine blood; leaves open translation to human acid-base kinetics.
The rate of pH decrease in dog blood after addition of CO2 (dissolved in saline) was measured in vitro with a combination pH electrode and fast-response amplifier. The pH change was found to have an apparent half time of 6.0 +/- 0.5 s at 38 degrees C, similar to that predicted by previous mathematical simulations on the basis of uncatalyzed CO2 hydration kinetics and the buffering characteristics of plasma. Measurements were also made in vivo in dogs by withdrawing blood rapidly from a carotid artery through a temperature-controlled chamber containing a pH electrode. When the flow was stopped, we measured the pH change which occurs in blood (after it leaves the lungs) as the slow dehydration of bicarbonate continues. The measured half time was 7.3 +/- 0.6 s, again agreeing well with predictions. Essentially the same half time was found when the direction of approach to chemical equilibrium was reversed by adding CO2 to the inspired air. The rate of the reactions could be increased markedly by hemolyzing the blood to release carbonic anhydrase into the plasma.
No takes yet. Share an insight, caveat, or question.
Hill et al. (1977) studied this question. Addition of CO2 was evaluated on Apparent half time of pH change. The apparent half time of pH change in dog blood after CO2 addition was 6.0 +/- 0.5 s in vitro and 7.3 +/- 0.6 s in vivo, matching predictions based on uncatalyzed CO2 hydration kinetics.
Synapse has enriched 10 related papers. Consider them for comparative context: