The objective of this study was to evaluate the feasibility of a new rapid adenosine triphosphate (ATP) bioluminescence method for monitoring surface hygiene in hospital pharmacy cleanrooms.It was assumed that, despite the low microbial load, the rapid method is sufficiently sensitive for routine use, and, due to its simplicity, useful as a rapid and effective tool for quality control, and also as a tool for detecting change and monitoring trends.A total of 537 surfaces in separate locations were randomly sampled with the traditional Replicate Organism Direct Area Contact (RODAC) imprint method (n = 484) to detect colony form units parallel to LuciPac Pen swabs (n = 992) to detect ATP load.The results were compared to assess correlation and to confirm the usefulness and limitations of the bioluminescent method.The statistical analyses were performed using McNemar's test, and Cohen's kappa coefficients of agreement were calculated for each room category.Defined cleanliness thresholds for LAF cabinets were 70 relative high units (RLU), for cleanrooms 140 RLU, and for filters 340 RLU.The results for the bioluminescent method largely confirm the data obtained with the standard culture method, and there was no significant difference in ability to predict unclean surfaces.However, despite the agreement of the results obtained, the analysis did not reveal a correlation between them.We concluded that bioluminescence can be useful as a supplementary method as a real-time surface hygiene monitoring tool to assess a room immediately before use.Faster access to data is an exceptional contribution to the quality and effectiveness of the process, as well as to product and patient safety. RezumatObiectivul acestui studiu a fost de a evalua fezabilitatea unei noi metode bioluminescente bazată pe adenozin trifosfat (ATP) pentru monitorizarea igienei suprafețelor din incintele curate ale farmaciei de spital.În ciuda încărcăturii microbiene scăzute, această metodă rapidă este suficient de sensibilă pentru a utilizarea ei în controlul calității, precum și ca instrument de estimare a tendințelor.537 suprafețe din locații diferite au fost analizate prin metoda RODAC (Replicate Organism Direct Area Contact) (n = 484) pentru detectarea unităților formatoare de colonii in comparație cu metoda bazată pe ATP (Pen-urile LuciPac) (n = 992).Analizele statistice au fost efectuate folosind testul McNemar, iar coeficienții Cohen au fost calculați pentru fiecare categorie de cameră.Pragurile de curățenie definite pentru incintele cu flux laminar de aer au fost de 70 de unități relative, pentru camere curate 140 unități și pentru filtre 340 unități.Rezultatele metodei bioluminiscente sunt comparabile cu cele obținute cu metoda standard și nu există diferențe semnificative în capacitatea de estimare a gradului de încărcare microbiană a suprafețelor.În concluzie metoda bioluminescentă poate fi folosită ca instrument de monitorizare a igienei suprafețelor în timp real pentru a evalua o cameră înainte de utilizare.
No takes yet. Share an insight, caveat, or question.
Mateja Tršan (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: