Key result
Polybrene neutralizes high-dose heparin without altering ETP whereas protamine yields limited reversal.
Why the study?
The anticoagulating and heparin-neutralizing properties of protamine and polybrene on plasma coagulability measured by endogenous thrombin potential were unclear.
Does polybrene neutralize high-dose heparin more effectively than protamine in vitro?
Does polybrene neutralize high-dose heparin more effectively than protamine in vitro?
In vitro experiments suggest polybrene is superior to protamine for neutralizing high doses of heparin, indicating current in vivo practices may need reconsideration.
Answers are grounded in this paper and cite their sources.
May support polybrene over protamine for high-dose heparin reversal in vitro; leaves open translation to in vivo or clinical use.
We investigated the anticoagulating and heparin-neutralizing properties of protamine and polybrene (hexadimethrine bromide), using the endogenous thrombin potential (ETP) as the parameter to access plasma coagulability. The hypocoagulability induced by high doses of heparin (3 IU/ml) could be reversed by addition of protamine to a very limited extent only. Polybrene on the other hand did neutralize heparin at the equivalent concentration and a two-fold excess did not influence the ETP parameters. In vivo neutralization of high-dose heparin with protamine should therefore be reconsidered. Our experiments suggest polybrene to be superior over protamine with respect to neutralization of high doses of heparin.
No takes yet. Share an insight, caveat, or question.
Rotteveel et al. (2009) studied Heparin-induced hypocoagulability. Polybrene (hexadimethrine bromide) vs. Protamine was evaluated on Endogenous thrombin potential (ETP). Polybrene neutralized high doses of heparin without influencing ETP parameters, whereas protamine reversed heparin-induced hypocoagulability to a very limited extent.
Synapse has enriched 10 related papers. Consider them for comparative context: