Key result
Systolic pulsus alternans magnitude during auto-entrainment predicts cardiovascular death with 90% sensitivity.
Why the study?
There is an ongoing need to noninvasively identify higher risk heart failure patients requiring more invasive investigations or interventions by improving predictive metrics with increased sensitivity.
Does auto-entrainment methodology predict cardiovascular death in patients with heart failure?
Cohort (n=148)
Does auto-entrainment methodology predict cardiovascular death in patients with heart failure?
Auto-entrainment methodology, specifically measuring systolic pulsus alternans, provides a noninvasive method to predict cardiovascular death in heart failure patients.
Answers are grounded in this paper and cite their sources.
May aid CV death risk stratification; leaves open prospective validation before clinical adoption.
BACKGROUND: Risk assessment studies use a suite of nominally independent noninvasive heart rate metrics, often brought together in a statistical model to compute a risk score. The ongoing need to noninvasively identify the higher risk patients requiring more invasive investigations/interventions drives the search for better noninvasive predictive metrics, with increased sensitivity. Many varieties of autoregulatory malfunction occur within the cardiovascular system; thus, it seems a daunting challenge to build predictive models that account for all potential modes of failure. Auto-entrainment (AE) methodology was developed to help address this challenge. METHODS AND RESULTS: AE methodology tests intrinsic capacity to maintain a stable and coherent oscillatory dynamic of autoregulatory control via respiratory entrainment of the blood pressure and heart period. Using cardiovascular death (n=18) at follow-up (1.5 years) as the end point, analysis of AE measurements from 148 patients with heart failure revealed 2 parameters significantly predictive of death. Using logistic regression, the magnitude of systolic pulsus alternans measured during AE had predictive sensitivity of 90% (confidence interval, 62%-100% and specificity of 62% (confidence interval, 49%-74%). The capacity to maintain a stable oscillatory dynamic was measured by the fraction of the total RR-interval spectral power contained within the AE-band. This capacity had predictive sensitivity of 73% (confidence interval, 47%-99%) and specificity of 55% (confidence interval, 43%-66%). CONCLUSIONS: AE methodology provides a noninvasive platform to assess the integrity of cardiovascular autoregulatory control systems for risk assessment in heart failure patients.
No takes yet. Share an insight, caveat, or question.
Roach et al. (2012) conducted a cohort in heart failure (n=148). Auto-entrainment (AE) methodology was evaluated on cardiovascular death. The magnitude of systolic pulsus alternans measured during auto-entrainment predicted cardiovascular death at 1.5 years with 90% sensitivity and 62% specificity.
Synapse has enriched 10 related papers. Consider them for comparative context: