Key result
Aqueous dantrolene degradation follows pseudo first-order kinetics with maximum stability at pH 7.4.
Why the study?
The stability and degradation mechanism of dantrolene in aqueous solutions across the human gastrointestinal pH range and temperatures were not fully characterized.
Dantrolene exhibits maximum stability in aqueous solution at pH 7.4 and 37℃, following pseudo first-order degradation kinetics.
Answers are grounded in this paper and cite their sources.
May guide dantrolene formulation at pH 7.4; leaves open in vivo and clinical translation.
The mechanism of degradation of dantrolene in aqueous buffer solutions was studied at various pH values in the range of pH 1.2-9.5 and at temperatures ranging from 25℃ to 75℃ to determine the optimum pH and temperature requirements for its stability and eventual product performance over the human gastrointestinal pH range. Dantrolene was analyzed by reversed phase ultra-performance liquid chromatographic (UPLC). Chromatographic separation was achieved on a Waters Acquity UPLC system using a Waters BEH C18 analytical column and Waters BEH C18 guard column. The compounds were eluted with a linear acetonitrile gradient (25%-75%) over three minutes with a buffer composition of 2.0 mM of sodium acetate at pH 4.5 for degradation studies. The flow rate was maintained at 0.5 mL/min. Column temperature was maintained at 35℃. Injection volume was 4 μL and the degradation products were detected by a photodiode array (PDA) detector at 375 nm. Degradation products, including compound B and C were analyzed by mass spectroscopy (MS) and nuclear magnetic resonance spectroscopy (NMR) and the degradation pathways were proposed. Degradation of dantrolene followed pseudo first–order kinetics and a V-shaped pH-rate profile over the pH range 1.2-9.5. The maximum stability was observed at pH 7.4 and 37℃. Although the focus of this paper was on the mechanism of hydrolysis of dantrolene, the poor aqueous solubility of dantrolene, the developed understanding can be utilized to improve the quality of the formulation and the risk associated with the extravasation of dantrolene sodium solution in its current form.
No takes yet. Share an insight, caveat, or question.
Khan et al. (2012) studied this question. Dantrolene in aqueous solution was evaluated on Degradation rate constant (kobs). Dantrolene degradation in aqueous solution followed pseudo first-order kinetics with a V-shaped pH-rate profile, demonstrating maximum stability at pH 7.4 and 37°C.
Synapse has enriched 10 related papers. Consider them for comparative context: