Key result
Lower baseline FMD is linked to CRT response.
Why the study?
Impaired endothelial function measured by flow-mediated dilation is associated with increased morbidity and mortality in heart failure and may help differentiate responders from non-responders to cardiac resynchronisation therapy.
Does baseline flow-mediated dilation predict response to cardiac resynchronisation therapy in patients with heart failure?
Observational (n=19)
Does baseline flow-mediated dilation predict response to cardiac resynchronisation therapy in patients with heart failure?
Absolute Event Rate: 2.9% vs 7.4%
p-value: p=<0.05
Baseline flow-mediated dilation may serve as a predictor of response to cardiac resynchronisation therapy in patients with heart failure.
OBJECTIVES: Cardiac resynchronisation therapy (CRT) improves morbidity and mortality in heart failure (HF). Impaired endothelial function, as measured by flow-mediated dilation (FMD) is associated with increased morbidity and mortality in HF and may help to differentiate responders from non-responders. METHODS: 19 patients were recruited, comprising 94% men, mean age 69±8 years, New York Heart Association functional classes II-IV, QRSd 161±21 ms and mean left ventricular ejection fraction 26±8%. Markers of response and FMD were measured at baseline, 6 and 12 months following CRT. RESULTS: 14 patients were responders to CRT. Responders had significant improvements in VO2 (12.6±1.7 to 14.7±1.5 mL/kg/min, p<0.05), quality of life score (44.4±22.9-24.1±21.3, p<0.01), left ventricular end diastolic volume (201.5±72.5 mL-121.3±72.0 mL, p<0.01) and 6-min walk distance (374.0±112.8 m at baseline to 418.1±105.3 m, p<0.05). Baseline FMD in responders was 2.9±1.9% and 7.4±3.73% in non-responders (p<0.05). CONCLUSIONS: Response to CRT at 6 and 12 months is predicted by baseline FMD. This study confirms that FMD identifies responders to CRT, due to endothelium-dependent mechanisms alone.
No takes yet. Share an insight, caveat, or question.
Warriner et al. (2016) conducted an observational in Heart failure (n=19). Baseline flow-mediated dilation (FMD) vs. Non-responders to CRT was evaluated on Baseline flow-mediated dilation (FMD) in responders vs non-responders (p=<0.05). Baseline flow-mediated dilation was significantly lower in responders to cardiac resynchronisation therapy compared to non-responders (2.9% vs 7.4%, p<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: