Key result
Tedisamil terminates atrial fibrillation at 100% efficacy in canine pacing and vagal models.
Why the study?
Tedisamil's efficacy in terminating atrial fibrillation had not been evaluated prior to this study.
Does tedisamil terminate atrial fibrillation in canine models?
Does tedisamil terminate atrial fibrillation in canine models?
The experimental antiarrhythmic drug tedisamil effectively and dose-dependently terminates atrial fibrillation and prevents its reinduction in canine models without causing ventricular arrhythmias.
Answers are grounded in this paper and cite their sources.
Tedisamil converts AF in two canine models; leaves open any role in human AF pending clinical trials.
INTRODUCTION: Tedisamil is an experimental bradycardic agent possessing action potential-prolonging effects. It has been proven effective in terminating ventricular arrhythmias in several animal models and atrial flutter in a conscious dog model. There are no reports to date evaluating tedisamil's efficacy in terminating atrial fibrillation (AF). METHODS AND RESULTS: Two different canine models of AF were used. One group of dogs (n = 6) was subjected to 28 days of chronic fibrillatory pacing at 50 Hz using an implantable neural stimulator. Sustained AF was achieved in all dogs within 14 days of initiating pacing. A second set of dogs (n = 5) had AF induced via bilateral vagal stimulation. Tedisamil 1 mg/kg was 100% effective in terminating AF in both models. Cardioversion was associated with a statistically significant prolongation of the fibrillatory cycle length immediately before return to normal sinus rhythm in both models. A dose-response trial was performed in the vagal AF group as well as in a second group of three dogs that underwent chronic fibrillatory pacing. The efficacy of tedisamil was dose dependent, with limited efficacy at 0.1 and 0.3 mg/kg intravenously in both models. Tedisamil was able to prevent reinduction of sustained AF 30 minutes after administration of 1 mg/kg in the chronic pacing model in all dogs. Side effects included minor hypersalivation in most dogs receiving the 1 mg/kg dose. No ventricular ectopy or arrhythmias were observed. CONCLUSION: Tedisamil is effective for conversion of sustained AF to normal sinus rhythm in two different models of AF.
No takes yet. Share an insight, caveat, or question.
Fischbach et al. (2001) studied Atrial fibrillation (canine models) (n=14). Tedisamil was evaluated on Termination of atrial fibrillation. Tedisamil /kg intravenously was 100% effective in terminating atrial fibrillation in both chronic pacing and vagal stimulation canine models.
Synapse has enriched 10 related papers. Consider them for comparative context: