Key result
MR velocity mapping quantifies QP/QS with significantly lower interobserver variability than radionuclide angiography.
Why the study?
The agreement between MR velocity mapping and first-pass radionuclide angiography to quantify pulmonary-to-systemic blood flow ratio in left-to-right cardiac shunts was investigated.
Does MR velocity mapping provide accurate and precise measurements of pulmonary-to-systemic blood flow ratio compared to radionuclide angiography in patients with left-to-right cardiac shunts?
Cross-Sectional (n=36)
Does MR velocity mapping provide accurate and precise measurements of pulmonary-to-systemic blood flow ratio compared to radionuclide angiography in patients with left-to-right cardiac shunts?
MR velocity mapping is an accurate and precise method for measuring shunt size in patients with left-to-right cardiac shunts, demonstrating lower interobserver variability than radionuclide angiography.
Answers are grounded in this paper and cite their sources.
MR velocity mapping shows lower variability than radionuclide angiography for QP/QS; leaves open whether it should supplant other methods in clinical shunt evaluation.
PURPOSE: To investigate the agreement between two noninvasive methods, magnetic resonance (MR) velocity mapping and first-pass radionuclide angiography, to quantify the pulmonary-to-systemic blood flow ratio (QP/QS) in adults, adolescents, and children with left-to-right cardiac shunts. MATERIALS AND METHODS: The accuracy and precision of MR velocity mapping were studied in 12 control subjects (six men, six women) and in a phantom. MR velocity mapping and radionuclide angiography were performed on the same day in 24 patients (16 adults, two adolescents, six children; five male patients, 19 female patients). RESULTS: The mean error in QP/QS at MR velocity mapping in phantom experiments was -1% +/- 1 (mean +/- SD). In control subjects, QP/QS at MR velocity mapping was 1.03 +/- 0.03, and the cardiac index was 3.1 L/min/m2 +/- 0.2 and 3.2 L/min/m2 +/- 0.3 for women and men, respectively. In patients, QP/QS at radionuclide angiography was 14% +/- 13, higher than at MR velocity mapping. Interobserver variability was four times higher for radionuclide angiography compared with MR velocity mapping, 0% + 16 versus 0% +/- 4 (n = 12). The difference between repeated MR flow measurements in the same vessel was -1% +/- 5 (n = 36). CONCLUSION: The data suggest that MR velocity mapping is accurate and precise for measurements of shunt size over the whole range of possible QP/QS values.
No takes yet. Share an insight, caveat, or question.
Arheden et al. (1999) conducted a cross-sectional in Left-to-right cardiac shunts (n=36). MR velocity mapping vs. First-pass radionuclide angiography was evaluated on Pulmonary-to-systemic blood flow ratio (QP/QS). MR velocity mapping accurately measured shunt size (QP/QS) with lower interobserver variability compared to radionuclide angiography.