Key result
Lower-body positive pressure raises central venous pressure and stimulates plasma atrial natriuretic factor release.
Why the study?
The effects of short repeated and extended increases in right atrial pressure on plasma atrial natriuretic factor levels in healthy humans were not well characterized.
Does intermittent or continuous lower-body positive pressure affect central venous pressure and atrial natriuretic factor in healthy volunteers?
Does intermittent or continuous lower-body positive pressure affect central venous pressure and atrial natriuretic factor in healthy volunteers?
p-value: p=<0.025
The ANF response to short-term increases in right atrial pressure is maximal within 10 minutes, whereas repeated or sustained pressure stimuli alter ANF release dynamics.
Hypothesis-generating for CVP-ANF links in healthy subjects; leaves open relevance to heart failure or hypertension.
In eight healthy volunteers undergoing 16 experiments in a cross-over design central venous pressure (CVP) and atrial natriuretic factor (ANF) in central venous plasma were measured during a 30 min control period followed by three separated periods of 10 min lower-body positive pressure (LBPP) or 90 min continuous LBPP induced by inflation of a military anti-G suit to evaluate the effect of short repeated and of extended increases in right atrial pressure on plasma ANF levels. CVP increased significantly during each of three separate periods of intermittent LBPP, and 15 min after application of continuous LBPP (P less than 0.025 for all). Blood pressure and heart rate did not change. During intermittent LBPP plasma ANF levels increased 10 min after the first inflation of the MAGT-suit (P = 0.013), but not after the second or third inflation. During continuous LBPP plasma ANF remained unchanged until 90 min after application of LBPP where a significant rise was observed (P = 0.023). The data demonstrate that the ANF response to short-term increases in right atrial pressure, as small as 2.5 mmHg, is maximal within 10 min and that repeated pressure stimuli may decrease ANF release. Sustained increases in right atrial pressure are not associated with increases in plasma ANF until long after initiation of the pressure stimulus suggesting rapid receptor-binding of ANF and that the ANF receptors might be saturated during continuously elevated ANF levels.
No takes yet. Share an insight, caveat, or question.
N. Kellers (1990) studied Healthy (n=8). Lower-body positive pressure (LBPP) vs. 30 min control period was evaluated on Central venous pressure (CVP) and atrial natriuretic factor (ANF) levels (p=<0.025). Lower-body positive pressure increased central venous pressure (P<0.025), with intermittent pressure increasing plasma ANF at 10 minutes (P=0.013) and continuous pressure at 90 minutes (P=0.023).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: