We describe operating principles and results obtained with a new detector element: the Gas Electron Multiplier (GEM). Consisting of a thin composite sheet with two metal layers separated by a thin insulator, and pierced by a regular matrix of open channels, the GEM electrode, inserted on the path of electrons in a gas detector, allows the transfer of charge with an amplification factor approaching ten. Uniform response and high rate capability are demonstrated. Coupled to another device, multiwire or micro-strip chamber, the GEM electrode permits higher gains or less critical operation; separation of the sensitive (conversion) volume and the detection volume have other advantages: a built-in delay (useful for triggering purposes), and the possibility of applying high fields on the photo-cathode of ring imaging detectors to improve efficiency. Multiple GEM grids in the same gas volume allow large amplification factors to be achieved in a succession of steps, leading to the realization of an effective gas-filled photomultiplier.