Key result
High Electrical Risk Score is linked to ~2.7-fold higher odds of appropriate ICD shocks.
Why the study?
The ability of the electrical risk score (ERS) to predict ventricular arrhythmias in heart failure patients with primary prevention ICDs remains unclear.
Observational (n=91)
No
Odds Ratio: 2.721 (95% CI 1.801–4.112)
p-value: p=<0.001
A higher Electrical Risk Score (≥3) derived from a standard 12-lead ECG is an independent predictor of appropriate ICD shocks in patients with heart failure and may aid in arrhythmic risk stratification.
May aid arrhythmic risk stratification in primary-prevention HF; extends ECG markers but leaves open prospective validation.
Background: Implantable cardioverter defibrillators (ICDs) are essential for the primary prevention of sudden cardiac death in heart failure (HF); however, appropriate shocks increase mortality and impair quality of life. The electrical risk score (ERS) is an electrocardiographic (ECG)-based composite index with proven prognostic value, but its ability to predict ventricular arrhythmias in HF remains unclear. This study aims to evaluate the predictive value of the ERS for ventricular arrhythmia-related ICD shocks in HF patients undergoing primary prevention ICD implantation. Methods: In this study, 91 patients with HF were followed for 12 months after ICD implantation. The ERS was calculated from baseline ECGs. Patients were grouped based on ERS (<3 vs. ≥3), according to receiver operating characteristic curve analysis. Multivariate logistic regression was used to evaluate predictors of appropriate ICD shocks, and predictive performance was compared using the DeLong test. Results: Thirty-five patients (38.5%) experienced at least one appropriate ICD shock. The median ERS was significantly higher in the shock group compared to the non-shock group (p < 0.001). Patients with ERS ≥ 3 had significantly higher rates of the anti-tachycardia pacing therapy (p < 0.001) and HF-related hospitalization (p = 0.004). ERS was an independent predictor of ICD shocks (p < 0.001), with superior discriminative performance (AUC 0.882) compared to most ECG markers, including frontal QRS T angle, QRS duration, Tp-e interval, and heart rate. Conclusions: The ERS was associated with ventricular arrhythmia-related ICD shocks in HF patients undergoing primary prevention ICD implantation. The ERS may identify patients at increased arrhythmic risk and guides follow-up and ICD management.
No takes yet. Share an insight, caveat, or question.
Aladağ et al. (2026) conducted an observational in Heart failure (n=91). Electrical Risk Score (ERS) vs. Lower ERS (< 3) was evaluated on Appropriate ICD shocks (aOR 2.721, 95% CI 1.801-4.112, p=<0.001). The Electrical Risk Score (ERS) was independently associated with appropriate ICD shocks in heart failure patients (aOR 2.721) and demonstrated strong discriminative performance (AUC 0.882).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: