Key result
Concomitant AVR during LVAD implantation is linked to ~48% higher early mortality.
Why the study?
Redo aortic valve replacement performed simultaneously with LVAD implantation carries potential for increased mortality, and no reports exist on concomitant valve-in-valve transcatheter AVR and LVAD implantation.
Cohort (n=15,267)
Yes
Answers are grounded in this paper and cite their sources.
May warrant caution with concomitant surgical AVR in LVAD patients; leaves open whether transcatheter alternatives reduce this risk.
Redo aortic valve replacement (AVR) performed simultaneously with left ventricular assist device (LVAD) implantation carries potential for increased mortality rates. Although transcatheter AVR has been used for patients with previous LVAD placement, no literature reports concomitant valve-in-valve transcatheter AVR and LVAD implantation. Our patient had severe aortic prosthetic valve deterioration and advanced heart failure. Given the risks associated with reoperative aortic valve surgery, we chose transcatheter AVR at the time of LVAD implantation. Transthoracic echocardiography results showed severe aortic prosthetic valve deterioration with moderate aortic regurgitation as well as severe left ventricular dysfunction (ejection fraction, 11%). After redosternotomy, we performed transcatheter AVR via the ascending aorta and subsequent LVAD implantation. The postoperative course was uneventful. Generally, patients with structural deterioration of a bioprosthetic valve who report for LVAD therapy present considerable challenges to the surgeon. Concomitant transcatheter AVR offers a less-invasive alternative to surgical AVR that minimizes ischemic injury to myocardium.
No takes yet. Share an insight, caveat, or question.
Murashita et al. (2017) conducted a cohort in End-stage heart failure requiring left ventricular assist device (LVAD) (n=15,267). Concomitant aortic valve (AoV) replacement vs. No aortic valve procedure was evaluated on Early (≤90 days post-LVAD surgery) survival (HR 1.477, 95% CI 1.154-1.890, p=0.002). Concomitant aortic valve replacement during continuous-flow LVAD implantation was independently associated with an increased risk of early all-cause mortality compared to no aortic valve procedure.
Synapse has enriched 10 related papers. Consider them for comparative context: