Answers are grounded in this paper and cite their sources.
A cubic CsI(TI) crystal of 0.8 cm on a side was mounted on a 1 x 1 cm square photodiode to measure the absolute scintillation yield of CsI(TI) between - 100 and + 50°C. The room temperature yield was measured to be 64,800 + 3,200 photons/MeV. The maximum yield was observed to occur at about -35°C, approximately 6% above the room temperature yield. The yield was observed to decrease monotonically above and below this maximum. At - 100 and + 50°C the yield was measured to be about 64% and 95% of the room temperature yield, respectively. Over the range of - 55 to + 50°C the scintillation yield was observed to remain within +6% of the room temperature yield. The temperature dependence of scintillation decay time, scintillation emission spectrum, and wavelengthdependent photodiode quantum efficiency were considered.
No takes yet. Share an insight, caveat, or question.
Valentine et al. (1993) studied this question.