Key result
Temperature-based rate-responsive leadless pacemakers increase exercise heart rate in ~100% of patients.
Why the study?
Previous studies evaluated motion-based sensors in tined-fixation leadless pacemakers, but literature evaluating the performance of temperature-based sensors in screw-fixation leadless pacemakers during exercise is limited.
Does the temperature-based sensor in screw-fixation leadless pacemakers provide appropriate heart rate adaptation during bicycle exercise testing in patients with a leadless pacemaker?
Cohort (n=7)
Does the temperature-based sensor in screw-fixation leadless pacemakers provide appropriate heart rate adaptation during bicycle exercise testing in patients with a leadless pacemaker?
Temperature-based sensors in screw-fixation leadless pacemakers successfully increase heart rate during exercise, though one-third of paced patients experienced a delayed peak response that required reprogramming if symptomatic.
Answers are grounded in this paper and cite their sources.
May warrant sensor optimization if symptomatic; extends rate-response observations but leaves open prospective validation.
Background Leadless pacemakers (LPs) rely on rate-responsive sensors for pacing during physical activity in patients with chronotropic incompetence or pacing-dependency. Previous studies evaluated the rate-responsiveness of motion-based sensors, used in tined-fixation LPs. However, for the temperature-based sensor (TBS), used in screw-fixation LPs, the existing literature is limited. Evaluating the performance of TBSs is clinically relevant to ensure appropriate heart rate (HR) adaptation during exercise. TBSs detect temperature changes in the central venous blood pool. An increase in temperature is interpreted as physical activity; the LP adjusts the pacing rate accordingly. Optimization of the TBS can be done by adjusting the gain setting or the maximum sensor rate (MSR). Objective The aim of this study is to assess the performance of the TBS during exercise in patients with a LP. Methods Patients with a screw-fixation LP and an activated TBS underwent an exercise test (ET) on a bicycle, where an ECG together with the performed workload (WL) was registered during the ET. Results Seven patients with a LP and activated TBS underwent an ET: four patients were implanted with a single atrial LP, two with a single ventricular LP, and one with a dual chamber LP. Six patients had a paced heart rhythm during the ET. Figure 1 illustrates the rate-responsive performance of the TBS in their LP. Pacemaker settings prior to the ET were nominal and not individually optimized except for patient 6, in whom settings were based on previous transvenous pacemaker parameters and a walking test. In 2 patients (#2, #3), 33%, a delayed sensor response was observed, with the highest HR occurring during the recovery phase rather than during peak exercise. In patient 2, the sensor gain was increased after the ET, which resulted in a reduction of symptoms. For patient 3, no adjustments were made, as they remained asymptomatic. In all patients, the HR remained elevated during the initial post-ET period, reflecting a physiological response that is also observed in individuals without pacemaker therapy. Conclusion The TBS used in the screw-fixation LP for rate-responsive pacing, demonstrates an increase in heart rate during exercise testing in all patients. In patients with a delayed peak HR response, optimization was achieved through reprogramming.
No takes yet. Share an insight, caveat, or question.
Velraeds et al. (2026) conducted a cohort in Chronotropic incompetence or pacing-dependency treated with a screw-fixation leadless pacemaker (n=7). Temperature-based sensor in screw-fixation leadless pacemakers was evaluated on Rate-responsive heart rate performance during bicycle exercise testing. Temperature-based sensors in screw-fixation leadless pacemakers increased heart rate during exercise in 100% of patients (7/7), though 33% (2/6 paced) had a delayed peak response.