Key result
Minimalistic BAV without onsite surgery achieves >=30% gradient reduction in ~93% of patients.
Why the study?
Balloon aortic valvuloplasty is traditionally performed in hospitals with onsite cardiac surgery due to potential complications, and the safety of a minimalistic approach by high-volume operators in a centre without onsite surgery required evaluation.
Does a minimalistic balloon aortic valvuloplasty strategy safely and effectively reduce invasive transvalvular gradients with low periprocedural complications in high-risk patients with severe symptomatic aortic stenosis treated at a centre without onsite cardiac surgery?
Observational (n=174)
No
Does a minimalistic balloon aortic valvuloplasty strategy safely and effectively reduce invasive transvalvular gradients with low periprocedural complications in high-risk patients with severe symptomatic aortic stenosis treated at a centre without onsite cardiac surgery?
Balloon aortic valvuloplasty using a minimalistic approach (ultrasound-guided access, radial approach, and guidewire pacing) can be safely and effectively performed in high-risk severe aortic stenosis patients at centres without onsite cardiac surgery.
Answers are grounded in this paper and cite their sources.
BAV without onsite surgery may be feasible in high-volume centers by trained operators; leaves open broader adoption pending prospective multicenter data.
Background: Balloon aortic valvuloplasty (BAV) is a palliative tool for patients with symptomatic severe aortic stenosis (AS) at prohibitive risk for surgery or as a bridge to surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). BAV is traditionally performed in hospitals with onsite cardiac surgery due to its potential complications. Aims: The aim of this study was to evaluate the safety of BAV procedures performed by trained high-volume operators in a centre without onsite surgery and to assess the effect of a minimalistic approach to reduce periprocedural complications. Methods: From 2016 to 2021, 187 BAV procedures were performed in 174 patients. Patients were elderly (mean age: 85.0±5.4 years) and had high-risk (mean European System for Cardiac Operative Risk Evaluation score [EuroSCORE] II: 10.1±9.9) features. According to the indications, 4 cohorts were identified: 1) bridge to TAVR (n=98; 56%); 2) bridge to SAVR (n=8; 5%); 3) cardiogenic shock (n=11; 6%); and 4) palliation (n=57; 33%). BAV procedures were performed using the standard retrograde technique via femoral access in 165 patients (95%), although radial access was used in 9 patients (5%). Ultrasound-guided vascular puncture was performed in 118 patients (72%) and left ventricular pacing was administered through a stiff guidewire in 105 cases (60%). Results: BAV safety was confirmed by 1 periprocedural death (0.6%), 1 intraprocedural stroke (0.6%), 2 major vascular complications (1%) and 9 minor vascular complications (5%). Nine cases of in-hospital mortality occurred (5%), predominantly in patients with cardiogenic shock. Conclusions: BAV is a safe procedure that can be performed in centres without onsite cardiac surgery using a minimalistic approach that can reduce periprocedural complications.
No takes yet. Share an insight, caveat, or question.
Iannopollo et al. (2024) conducted an observational in Severe symptomatic aortic stenosis (n=174). Minimalistic balloon aortic valvuloplasty (BAV) was evaluated on Reduction of the invasive peak-to-peak gradient >=30% (p=0.007). Minimalistic balloon aortic valvuloplasty in a center without onsite surgery achieved >=30% invasive gradient reduction in 93% of cases with 0.6% periprocedural and 5.2% in-hospital mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: