Key result
CF-LVAD and PF-LVAD provide sustained reductions in mean pulmonary artery pressure posttransplant.
Why the study?
Whether the improvement in pulmonary hemodynamics achieved by left ventricular unloading with LVADs is sustained long term after heart transplantation was unclear.
Does continuous-flow LVAD support compared to pulsatile-flow LVAD support sustain improvements in pulmonary vascular hemodynamics up to 5 years after heart transplantation?
Cohort (n=38)
Does continuous-flow LVAD support compared to pulsatile-flow LVAD support sustain improvements in pulmonary vascular hemodynamics up to 5 years after heart transplantation?
Long-term LVAD support significantly improves pulmonary artery pressures regardless of whether a continuous-flow or pulsatile-flow device is used, and these hemodynamic benefits are sustained 3 to 5 years after heart transplantation.
Answers are grounded in this paper and cite their sources.
LVAD support was associated with sustained posttransplant pulmonary pressure reduction irrespective of flow type; leaves open device-specific effects in randomized trials.
It is unclear whether pulmonary hemodynamics improvement with left ventricle unloading with left ventricular assist devices (LVADs) is sustained long term after heart transplant (HT). We sought to assess the effects on pulmonary vascular hemodynamics during continuous-flow (CF-LVAD) and pulsatile flow (PF-LVAD) support up to 5 years after HT. Invasive hemodynamics were evaluated before LVAD, before HT, and at 3 months, 1, and 3-5 years posttransplant. Thirty-eight patients were included in the study and divided into two groups according to the type of LVAD support. The two groups were well matched in age and gender. Mean pulmonary artery pressure (PAPm) and systolic PAP (PAPs) improved significantly in the PF-LVAD group (40 ± 10.6 to 19.8 ± 4.4 mm Hg and 62.7 ± 14.9 to 31.8 ± 5.9 mm Hg, respectively) and in the CF-LVAD group (37.4 ± 11.6 to 22.4 ± 7.7 mm Hg and 53.7 ± 18.0 to 34.6 ± 11.8 mm Hg, respectively). Reductions in PAPm and PAPs were more pronounced in PF-LVAD group than in CF-LVAD group (p = 0.005 and p = 0.03, respectively). After HT, the improvement in PAPm and PAPs was sustained after 3-5 years in patients who received PF-LVAD (22.6 ± 6.5 and 32.2 ± 9.2 mm Hg, respectively) and in patients who received CF-LVAD (22.2 ± 8.4 and 33.8 ± 9.6 mm Hg, respectively). In conclusion, long-term LVAD support resulted in significant improvement in PAPm and PAPs regardless of the pump generation. The improvement in hemodynamics observed during LVAD support was sustained 3-5 years posttransplant.
No takes yet. Share an insight, caveat, or question.
Saidi et al. (2017) conducted a cohort in Heart failure bridged to heart transplantation with left ventricular assist devices (n=38). Continuous-flow left ventricular assist device (CF-LVAD) vs. Pulsatile-flow left ventricular assist device (PF-LVAD) was evaluated on Mean pulmonary artery pressure (PAPm) and systolic pulmonary artery pressure (PAPs) (p=0.005). Both CF-LVAD and PF-LVAD reduced mean pulmonary artery pressure before transplant, with improvements sustained 3-5 years posttransplant.
Synapse has enriched 10 related papers. Consider them for comparative context: