Key result
Commercial EVOQUE TTVR eliminates severe TR in ~99% of patients, with ~13% 1-year mortality.
Why the study?
One-year real-world data following commercial transcatheter tricuspid valve replacement (TTVR) were lacking.
What are the one-year clinical, echocardiographic, and functional outcomes of commercial transcatheter tricuspid valve replacement with the EVOQUE system in real-world patients?
Cohort (n=237)
Yes
What are the one-year clinical, echocardiographic, and functional outcomes of commercial transcatheter tricuspid valve replacement with the EVOQUE system in real-world patients?
In this multicenter real-world European cohort, commercial TTVR with the EVOQUE system achieved durable 1-year TR elimination (≤mild in 98.6%), marked NYHA class improvement, and favorable biventricular remodeling, though with a 19.8% new pacemaker rate and 12.8% one-year mortality.
Answers are grounded in this paper and cite their sources.
Provides early real-world one-year TTVR outcomes; leaves open need for randomized trials before practice change.
Background One-year real-world data following transcatheter tricuspid valve replacement (TTVR) are lacking. Objectives We investigated one-year outcomes of commercial TTVR at 11 expert European heart valve centers. Methods Consecutive patients undergoing TTVR with the EVOQUE system after regulatory approval (October 2023-July 2025) were included in this single-arm, retrospective, multicenter study. Results Among 237 patients undergoing TTVR (median age 80 [74-84] years; 158 [66.7%] women; median TRI-SCORE 5 [3-6]), one-year vital status was available in 226(95.4%). The median follow-up time was 367 (217-448) days. After TTVR, paravalvular leak (PVL)≥mild was present in 31/201 (15.4%) and ≥moderate in 4/201 (2.0%). In-hospital permanent pacemaker implantation (PPI) was required in 33/166 pacemaker-naïve patients (19.8%). At one-year, tricuspid regurgitation (TR) was reduced to mild or less in 136/138(98.6%), while NYHA class III/IV decreased from 83.1% (95%CI 76.3-88.3) to 18.9% (95%CI 13.4-26.0, P <0.001). RV basal diameter decreased by -4.0 mm (95%CI -6.0 to -2.0, P <0.001), while LV end-diastolic volume increased by +11.8 mL (95%CI +4.2 to +19.4, P =0.003) and left atrial volume by +15.2 mL (95%CI +4.6 to +25.8, P =0.006), with unchanged LVEF. Twenty-six patients died at follow-up (12.8%, 95%CI 8.9-18.3). Patients with PVL experienced higher rates of one-year mortality, whereas TRI-SCORE was independently associated with the composite endpoint of death or heart failure hospitalization (hazards ratio 1.26 per point, 95%CI 1.06-1.50). Conclusions Commercial TTVR provided durable TR reduction, functional improvement, and biventricular remodeling at one-year follow-up. Baseline disease stage characterized by higher TRISCORE and procedural complications might be associated with increased risk of adverse events.
No takes yet. Share an insight, caveat, or question.
Angellotti et al. (2026) conducted a cohort in Tricuspid regurgitation undergoing transcatheter tricuspid valve replacement (n=237). Transcatheter tricuspid valve replacement (TTVR) with the EVOQUE system was evaluated on One-year all-cause mortality (95% CI 8.9-18.3). Commercial TTVR with the EVOQUE system reduced TR to ≤mild in 98.6% of patients at 1 year, with 12.8% mortality and NYHA III/IV decreasing from 83.1% to 18.9%.