Key result
The pre-procedure shortest QRS duration from a 12-lead ECG was an independent predictor for echocardiographic response to cardiac resynchronization therapy at 6 months.
Why the study?
Does the shortest QRS duration from a 12-lead ECG predict response to cardiac resynchronization therapy in patients with heart failure and complete LBBB?
Observational (n=61)
Does the shortest QRS duration from a 12-lead ECG predict response to cardiac resynchronization therapy in patients with heart failure and complete LBBB?
The shortest QRS duration measured from a standard 12-lead ECG is an independent predictor of response to cardiac resynchronization therapy, outperforming average and longest QRS durations.
Answers are grounded in this paper and cite their sources.
Shortest QRS duration may aid CRT response prediction in LBBB HF; leaves open incremental value and prospective validation before practice change.
QRS duration has been associated with the response to cardiac resynchronization therapy (CRT). However, the methods for defining QRS duration to predict the outcome of CRT have discrepancies in previous reports. The aim of this study was to determine an optimal measurement of QRS duration to predict the response to CRT.Sixty-one patients who received CRT were analyzed. All patients had class III-IV heart failure, left ventricular ejection fraction not more than 35%, and complete left bundle branch block. The shortest, longest, and average QRS durations from the 12 leads of each electrocardiogram (ECG) were measured. The responses to CRT were determined using the changes in echocardiography after 6 months. Thirty-five (57.4%) patients were responders and 26 (42.6%) patients were non-responders. The pre-procedure shortest, average, and longest QRS durations and the QRS shortening (ΔQRS) of the shortest QRS duration were significantly associated with the response to CRT in a univariate logistic regression analysis (P = 0.002, P = 0.03, P = 0.04 and P = 0.04, respectively). Based on the measurement of the area under curve of the receiver operating characteristic curve, only the pre-procedure shortest QRS duration and the ΔQRS of the shortest QRS duration showed significant discrimination for the response to CRT (P = 0.002 and P = 0.038, respectively). Multivariable logistic regression showed the pre-procedure shortest QRS duration is an independent predictor for the response to CRT.The shortest QRS duration from the 12 leads of the electrocardiogram might be an optimal measurement to predict the response to CRT.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2017) conducted an observational in Heart failure (n=61). Shortest QRS duration measurement vs. Average and longest QRS duration measurements was evaluated on Response to CRT determined using changes in echocardiography (p=0.002). The pre-procedure shortest QRS duration from a 12-lead ECG was an independent predictor for echocardiographic response to cardiac resynchronization therapy at 6 months.
Synapse has enriched 10 related papers. Consider them for comparative context: