Key result
The presence of a lipid core within the plaque was the only independent predictor of an abnormal coronary flow reserve response after successful coronary stenting (OR 33.08).
Why the study?
Do specific plaque characteristics on intravascular ultrasound predict a reduction in coronary flow reserve after percutaneous coronary intervention in patients with coronary artery disease?
Observational (n=69)
No
Do specific plaque characteristics on intravascular ultrasound predict a reduction in coronary flow reserve after percutaneous coronary intervention in patients with coronary artery disease?
Effect estimate: OR 33.08 (95% CI 1.99-549.35)
p-value: p=0.015
The presence of a lipid core on intravascular ultrasound is a significant predictor of reduced coronary flow reserve after PCI, suggesting a higher risk of microembolization.
Background and Objectives:A reduction of the coronary flow reserve (CFR) following successful percutaneous coronary intervention (PCI) is related to microvascular impairment. Embolization of atherosclerotic debris during PCI is a possible explanation for the finding of abnormal coronary Doppler flow following PCI. Subjects and Methods:The CFR and intravascular ultrasound (IVUS), both before and after PCI, were recorded in 69 lesions of 69 patients with coronary artery disease. An abnormal CFR was defined as one with no change or a decrease after successful PCI. Results:The patients were divided into abnormal (n=17) and normal CFR (n=52) groups. After stenting, the hyperemic flow velocity was significantly lower in the abnormal CFR group (39.3±12.6 vs. 48.9± 15.4 cm/s, p=0.022). 94 and 29% of the abnormal group had soft plaques and lipid cores, respectively, compared with 62 and 2% in the normal CFR group (soft plaque: p=0.029, lipid core: p=0.002). The abnormal CFR group had smaller post-procedural vessels (15.1±4.2 vs. 18.2±4.9 mm, p=0.039) and plaque areas (6.8±2.7 vs. 9.9± 3.8 mm, p=0.006). Furthermore, the abnormal CFR group showed less vessel expansion (1.7±5.5 vs. 5.0±3.9 mm, p=0.018) and greater plaque loss (4.1±5.3 vs. 0.7±3.4 mm, p=0.009). The abnormal CFR group had an increased CK-MB following PCI (4 patients, 23.5% vs. 2 patients, 3.8%, p=0.029). In a multivariable analysis, the only predictor of an abnormal CFR was the presence of a lipid core within the plaque. Conclusion:Soft plaques, the presence of a lipid core and a large reduction in plaques increase the risk of microembolization during the PCI procedure. (Korean Circulation J 2006;36:192-199)
No takes yet. Share an insight, caveat, or question.
Choi et al. (2006) conducted an observational in Coronary Artery Disease (n=69). Presence of lipid core vs. Absence of lipid core was evaluated on Abnormal coronary flow reserve (CFR) response after stenting (OR 33.08, 95% CI 1.99-549.35, p=0.015). The presence of a lipid core within the plaque was the only independent predictor of an abnormal coronary flow reserve response after successful coronary stenting (OR 33.08).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: