Key result
Dual-energy CT-derived iodine concentration and effective atomic number improved the differentiation of left atrial appendage thrombus from spontaneous echo contrast compared to conventional Hounsfield units.
Why the study?
The study aimed to assess the diagnostic performance of dual-energy CT-derived iodine concentration and effective atomic number in early-phase cardiac CT for detecting LAA thrombus and differentiating it from spontaneous echo contrast in patients with AF.
Does dual-energy CT-derived iodine concentration and effective atomic number improve the detection of LAA thrombus compared to conventional Hounsfield units in patients with atrial fibrillation?
Cross-Sectional (n=389)
Single-blind
No
Does dual-energy CT-derived iodine concentration and effective atomic number improve the detection of LAA thrombus compared to conventional Hounsfield units in patients with atrial fibrillation?
Dual-energy CT-derived iodine concentration and effective atomic number significantly improve the diagnostic accuracy of early-phase cardiac CT for detecting LAA thrombus compared to conventional Hounsfield units.
Answers are grounded in this paper and cite their sources.
May improve noninvasive LAA thrombus detection on CT in AF; leaves open prospective validation before clinical use.
Aims This study aimed to assess the diagnostic performances of dual-energy computed tomography (CT)-derived iodine concentration and effective atomic number (Z eff ) in early-phase cardiac CT in detecting left atrial appendage (LAA) thrombus and differentiating thrombus from spontaneous echo contrast (SEC) in patients with atrial fibrillation using transesophageal echocardiography (TEE) as the reference standard. Methods and results A total of 389 patients with atrial fibrillation were prospectively recruited. All patients underwent a single-phase cardiac dual-energy CT scan using a third-generation dual-source CT. The iodine concentration, Z eff , and conventional Hounsfield units (HU) in the LAA were measured and normalized to the ascending aorta (AA) of the same slice to calculate the LAA/AA ratio. Of the 389 patients, TEE showed thrombus in 15 (3.9%), SEC in 33 (8.5%), and no abnormality in 341 (87.7%) patients. Using TEE findings as the reference standard, the respective sensitivity, specificity, positive predictive value, and negative predictive value of the LAA/AA HU ratio for detecting LAA thrombus were 100.0, 96.8, 55.6, and 100.0%; those of the LAA/AA iodine concentration ratio were 100.0, 99.2, 83.3, and 100.0%; and those of the LAA/AA Z eff ratio were 100.0, 98.9, 79.0, and 100.0%. The areas under the receiver operator characteristic curve (AUC) of the LAA/AA iodine concentration ratio (0.978; 95% CI 0.945–1.000) and Z eff ratio (0.962; 95% CI 0.913–1.000) were significantly larger than that of the LAA/AA HU ratio (0.828; 95% CI 0.714–0.942) in differentiating the thrombus from the SEC (both P < 0.05). Although the AUC of the LAA/AA iodine concentration ratio was larger than that of the LAA/AA Z eff ratio, no significant difference was found between them ( P = 0.259 ). Conclusion The dual-energy CT-derived iodine concentration and the Z eff showed better diagnostic performance than the conventional HU in early-phase cardiac CT in detecting LAA thrombus and differentiating the thrombus from the circulatory stasis. However, these results need to be validated in large-cohort studies with late-phase images.
No takes yet. Share an insight, caveat, or question.
Li et al. (2022) conducted a cross-sectional in Atrial fibrillation (n=389). Dual-energy CT-derived iodine concentration and effective atomic number (Z eff) vs. Conventional Hounsfield units (HU) was evaluated on Area under the receiver operating characteristic curve (AUC) for differentiating thrombus from spontaneous echo contrast (95% CI 0.945-1.000, p=<0.05). Dual-energy CT-derived iodine concentration and effective atomic number improved the differentiation of left atrial appendage thrombus from spontaneous echo contrast compared to conventional Hounsfield units.