Key result
Timed electrical pulse prevents reperfusion-induced ventricular tachycardia with a ~100-point absolute reduction in mice.
Why the study?
Does a single precisely timed electrical pulse within the protective period prevent reperfusion-induced ventricular tachycardia in conscious mice?
Does a single precisely timed electrical pulse within the protective period prevent reperfusion-induced ventricular tachycardia in conscious mice?
A precisely timed electrical pulse within the protective period of the cardiac cycle can prevent reperfusion-induced ventricular tachycardia in a conscious mouse model.
Answers are grounded in this paper and cite their sources.
May inform device-based arrhythmia prevention strategies; leaves open translation beyond conscious mouse models.
Early pioneering investigators discovered, in anesthetized dogs, a protective period within the cardiac cycle. The protective period was a time within the cardiac cycle when a precisely timed stimulus prevented the initiation of ventricular fibrillation caused by an earlier stimulus. Thus, in addition to the susceptible period of repolarization discussed by Wiggers and Wegria (Am. J. Physiol. 131:296, 1940; Am. J. Physiol. 128:500, 1940), there is also a nearby protective period. This report describes a protective period within the cardiac cycle of conscious mice when a precisely timed stimulus prevented the initiation of ventricular tachycardia caused by an earlier stimulus. In addition, we tested the hypothesis that this precisely timed pulse within the protective period prevents reperfusion-induced ventricular tachyarrhythmias in conscious mice. Mice (n = 6) were prepared to record arterial blood pressure and the electrocardiogram. In addition, a vascular occluder was placed around the left main coronary artery, and stimulating electrodes were secured onto the left ventricle. A single precisely timed electrical pulse (5 msec pulse width and 2.5 V) to the left ventricle arriving 13.9 ± 1.1 msec after the R-wave, caused ventricular tachycardia occurring 24.9 ± 0.9 msec after the R-wave. Importantly, a second precisely timed electrical pulse arriving 18.8 ± 0.5 msec after the first stimulus blocked the induction of ventricular tachycardia caused by the earlier stimulus. On an alternate day, the susceptibility to sustained ventricular tachycardia produced by 3.5 min of occlusion and reperfusion of the coronary artery was determined in conscious mice by use of the vascular occluder. Reperfusion resulted in ventricular tachycardia in all six mice. A precisely timed pulse within the protective period prevented ventricular tachycardia in all mice.
No takes yet. Share an insight, caveat, or question.
Lujan et al. (2018) studied Reperfusion-induced ventricular tachycardia (n=6). Precisely timed single electrical pulse within the protective zone of the cardiac cycle vs. No electrical pulse (ischemia-reperfusion alone control protocol) was evaluated on Incidence of reperfusion-induced ventricular tachycardia. A precisely timed single electrical pulse within the protective zone of each cardiac cycle prevented reperfusion-induced ventricular tachycardia in 100% of tested conscious mice.