Why the study?
Does varying oxygen content in hemoglobin solutions affect coronary flow, heart rate, myocardial oxygen consumption, and tension in isolated rabbit hearts?
Does varying oxygen content in hemoglobin solutions affect coronary flow, heart rate, myocardial oxygen consumption, and tension in isolated rabbit hearts?
In isolated rabbit hearts, decreasing oxygen content in the perfusate increases coronary flow while maintaining constant heart rate, myocardial tension, and oxygen consumption above 2 vol. % oxygen capacity.
Answers are grounded in this paper and cite their sources.
Indicates oxygen-dependent coronary flow regulation in isolated hearts; leaves open translation to in vivo human physiology.
Coronary flow, heart rate, myocardial oxygen consumption and Walton strain gauge tension were determined in the isolated rabbit heart perfused with hemoglobin solutions of varying oxygen content. Perfusion was carried out under constant pressure and with the hemoglobin solution in equilibrium with 3% CO 2 and 97% air under atmospheric tension. Oxygen content was varied from 2 to 18 vol. % by diluting hemoglobin with Ringer-Locke solution. Change from a higher to lower oxyhemoglobin concentration resulted in increased coronary flow; the reserve led to decreased flow. Heart rate, myocardial tension and oxygen consumption were constant at oxygen capacity above 2 vol. %.
No takes yet. Share an insight, caveat, or question.
Guz et al. (1960) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: