Key result
Retained CIED components were present in 42% of patients undergoing heart transplantation and were associated with serious adverse events, but not with reduced long-term survival.
Why the study?
Are retained CIED components common after heart transplantation and do they lead to adverse events or reduced long-term survival?
Cohort (n=206)
No
Are retained CIED components common after heart transplantation and do they lead to adverse events or reduced long-term survival?
Answers are grounded in this paper and cite their sources.
Retained CIED components are common (42%) after heart transplantation and can cause serious adverse events, highlighting the need for surgeons to be familiar with complete extraction techniques.
Aims: Many patients have a cardiac implantable electronic device (CIED) extracted at the time of heart transplantation. CIED components may be retained after heart transplantation, but their frequency, nature, and clinical significance is uncertain. Methods and results: Consecutive patients that underwent heart transplantation over 10 years from 1 January 2007 until 1 January 2017 were identified from the unit database. Pre- and post-operative chest radiographs were reviewed by two independent observers for the presence of CIED components. Adverse events relating to any retained CIED component were recorded. Two hundred and six patients had a CIED removed at the time of transplantation. Retained CIED components were present in 86 (42%) patients. The most common retained CIED components were suture sleeves and superior vena cava (SVC) coils of dual coil implantable cardioverter-defibrillator (ICD) leads. An SVC coil was retained in 25% of patients that had a dual coil ICD lead. Seven adverse events were associated with CIED removal or retained CIED components, including one fatal event. However, retained CIED components were not associated with reduced long-term survival after heart transplantation. Conclusion: Retained CIED components were seen in 42% of patients that had a CIED prior to transplantation, may be associated with serious adverse events but are not associated with reduced long-term survival. Cardiac surgeons should be aware of all CIED system components and be familiar with techniques for their complete removal at the time of transplantation.
No takes yet. Share an insight, caveat, or question.
Pettit et al. (2017) conducted a cohort in Heart transplantation with prior cardiac implantable electronic device (CIED) (n=206). Retained CIED components vs. Complete CIED removal was evaluated on Presence of retained CIED components. Retained CIED components were present in 42% of patients undergoing heart transplantation and were associated with serious adverse events, but not with reduced long-term survival.
Synapse has enriched 10 related papers. Consider them for comparative context: