Key result
Peridevice leaks at 6 weeks post-Watchman device implantation predominantly localized to the posterior 6:00-12:00 segment (39 of 45 leaks), with a mean leak size of 2.67 mm.
Why the study?
Postimplantation leaks are known sequelae of left atrial appendage occlusion with the Watchman device, but leak locations and characteristics are poorly described.
What is the location and frequency of peridevice leaks 6 weeks after left atrial appendage occlusion with the Watchman device?
Cohort (n=101)
What is the location and frequency of peridevice leaks 6 weeks after left atrial appendage occlusion with the Watchman device?
Post-Watchman device implantation leaks at 6 weeks predominantly localize to the posterior LAA ostium, which can be systematically mapped using a novel clock-face method.
Answers are grounded in this paper and cite their sources.
Posterior leak predominance may refine post-Watchman TEE protocols; leaves open whether clock-face mapping improves outcomes in future LAAO studies.
OBJECTIVES: To propose a novel method for mapping leak location and frequency to a clock-face representation of the left atrial appendage (LAA) ostium. BACKGROUND: LAA occlusion with the Watchman device (WD) is an established therapy to reduce thromboembolic events in patients with atrial fibrillation (AF) and intolerance to long-term oral anticoagulation. Postimplantation leaks are known sequelae, but leak locations and characteristics are poorly described. METHODS: We retrospectively reviewed 101 consecutive WD implants from April 2015 to February 2018. Leak locations from 6-week post-implant transesophageal echocardiograms were mapped to a clock-face representation of the LAA ostium: 12:00 as cranial near the limbus, 3:00 as anterior toward the pulmonary artery, 6:00 as caudal near the mitral annulus, and 9:00 as posterior. Patient demographics, LAA dimensions, and procedural characteristics were also collected. RESULTS: VASc 4.69, and 64% of patients with permanent AF. No patient had a detectable leak at the time of implant. At 6 weeks, mean leak size was 2.67 ± 0.89 mm with no leak over 5 mm (largest 4.60 mm). Most leaks occurred along the posterior 6:00-12:00 segment (39/45) and the 6:00-9:00 quadrant (16/45). CONCLUSION: Six-week post-WD implant leaks localize to the posterior LAA ostium. This could result from the elliptical LAA orifice, differential LAA tissue composition, or implantation technique. This study provides a novel method for describing the location of post-implant leaks and serves as the basis for further investigations.
No takes yet. Share an insight, caveat, or question.
Westcott et al. (2020) conducted a cohort in Atrial fibrillation (n=101). Watchman device implantation was evaluated on Peridevice leak location and size at 6 weeks. Peridevice leaks at 6 weeks post-Watchman device implantation predominantly localized to the posterior 6:00-12:00 segment (39 of 45 leaks), with a mean leak size of 2.67 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: