Key result
Fetal coarctation of the aorta is linked to ~19-point lower aortic global circumferential strain.
Why the study?
Abnormal aortic elastic properties are a major vasculopathy in coarctation of the aorta, but there were no reports evaluating aortic wall elastic characteristics in fetuses with the condition.
Are aortic elastic properties impaired in fetuses with coarctation of the aorta compared to normal fetuses?
Case-Control (n=112)
Single-blind
No
Are aortic elastic properties impaired in fetuses with coarctation of the aorta compared to normal fetuses?
Velocity vector imaging reveals that fetuses with coarctation of the aorta exhibit measurable impairments in ascending aortic elastic properties in utero, which negatively correlate with ventricular function.
Answers are grounded in this paper and cite their sources.
Supports early aortic strain assessment in fetal coarctation; hypothesis-generating and should not yet change prenatal management.
Background Abnormal aortic elastic properties are major notable vasculopathy involved in coarctation of the aorta (CoA). However, there are no reports on aortic wall elastic characteristics in fetuses with CoA. Methods and Results Fifty‐six fetuses with CoA and 56 normal controls were included in this prospective case–control study. The dimensions of the cardiac chamber, the size of the aorta, left ventricular myocardial performance indexes, and aortic elastic properties, including the global circumferential strain, fractional area change and mean longitudinal strain, were measured serially in utero. The global circumferential strain, fractional area change, and mean longitudinal strain in fetuses with CoA were smaller than those in the normal group at both the first and last examinations (18.50% versus 37.73% for global circumferential strain, 38.90% versus 57.55% for fractional area change, 6.61% versus 11.81% for mean longitudinal strain at first scan, 16.62% versus 42.05% for global circumferential strain, 36.54% versus 59.7% for fractional area change, 6.2% versus 11.46% for mean longitudinal strain at last scan, all P <0.001). There were negative correlations between aortic elastic properties and left ventricular myocardial performance indexes in fetuses with CoA ( P <0.01). Aortic elastic properties were correlated positively with aortic isthmus size in fetuses with CoA ( P <0.01). Conclusions Aortic strain and the fractional area change were decreased in fetuses with CoA. Impairments of these aortic elastic properties were associated with diminished heart function and aortic isthmus size in utero. Further large‐scale longitudinal studies are required to confirm the potential predictive value of cardiovascular morbidity (ie, hypertension) in fetuses with CoA.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2023) conducted a case-control in Coarctation of the aorta in fetuses (n=112). Coarctation of the aorta vs. Normal fetuses was evaluated on Differences in aortic elastic properties (global circumferential strain, fractional area change, and mean longitudinal strain) (p=<0.001). Fetuses with coarctation of the aorta had reduced aortic global circumferential strain at the first scan compared to normal controls, indicating impaired aortic elastic properties in utero.
Synapse has enriched 10 related papers. Consider them for comparative context: