Why the study?
Does the Dinamap automated oscillometric blood pressure monitor accurately measure blood pressure compared to random-zero sphygmomanometry and radial artery catheters in ambulatory and surgical patients?
Does the Dinamap automated oscillometric blood pressure monitor accurately measure blood pressure compared to random-zero sphygmomanometry and radial artery catheters in ambulatory and surgical patients?
The Dinamap automated oscillometric blood pressure monitor shows significant differences in systolic and diastolic pressure readings compared to standard sphygmomanometry and intra-arterial catheters, highlighting the need for caution when relying on these measurements in critical settings.
Answers are grounded in this paper and cite their sources.
May warrant caution interpreting Dinamap systolic values; leaves open device-specific validation against intra-arterial standards.
The validity of the Dinamap automated oscillometric blood pressure monitor, an instrument frequently used for continuous monitoring in intensive care settings, was evaluated in comparison to two standard methods of blood pressure measurement. Oscillometric monitoring was compared to random-zero sphygmomanometry in 28 ambulatory subjects, using the instruments in a random order. The oscillometric monitor overestimated random-zero systolic pressure (mean difference = 5.7 mm Hg; P less than 0.001), but did not differ in diastolic pressure (difference = 1.3 mm Hg, P greater than 0.3). Correlation (r) between methods was 0.94 for systolic pressure and 0.83 for diastolic pressure. Repeatability of sequential measures did not differ between methods. To evaluate the oscillometric monitor in the intraoperative setting, it was used simultaneously with a radial artery catheter to measure blood pressure in 14 patients undergoing peripheral vascular or other major surgery. The oscillometric monitor underestimated intra-arterial systolic pressure (mean difference = -9.4 mm Hg; P less than 0.002), but overestimated intraarterial diastolic pressure (difference = 5.7 mm Hg; P less than 0.005). There was no difference in mean arterial pressure (P greater than 0.1). Correlation between methods was 0.88 for systolic, 0.71 for diastolic, and 0.79 for mean arterial pressure. The oscillometric instrument had a sensitivity of 63% and specificity of 97% in detecting intraarterial systolic pressures of 160 mm Hg or greater, and a sensitivity of 89% and specificity of 89% in detecting intraarterial systolic pressures of 100 mm Hg or less. These findings demonstrate differences between the oscillometric monitor and other standard methods of blood pressure measurement.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Manolio et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: