Why the study?
RFA lesions are usually only assessed functionally without direct visualization of immediate tissue effects, which optical coherence tomography might enable with high resolution.
Does optical coherence tomography accurately assess radiofrequency ablation lesion dimensions compared to histology in a porcine model?
Does optical coherence tomography accurately assess radiofrequency ablation lesion dimensions compared to histology in a porcine model?
Optical coherence tomography provides high-resolution visual assessment of radiofrequency ablation lesions that correlates strongly with histology in a preclinical model.
Answers are grounded in this paper and cite their sources.
OCT may enable direct visualization of RFA lesions in AF; leaves open whether it improves outcomes or warrants clinical adoption.
BACKGROUND: Radiofrequency catheter ablation (RFA) is an effective treatment for atrial fibrillation. However, ablation lesions are usually only assessed functionally. The immediate effect of RFA on the tissue is not directly visualized. Optical coherence tomography (OCT) is an imaging technique that uses light to capture high-resolution images with histology-like quality. Therefore, it might be used for high-precision imaging of ablation lesions. METHODS AND RESULTS: Radiofrequency ablation lesions (n = 25) were produced on the freshly excised left and right ventricular porcine endocardium. A Thermocool ST SF NAV ablation catheter (Biosense Webster Inc) and an EP-Shuttle ablation generator (Stockert GmbH) were used to produce ablation lesions with powers from 10 to 40 W (energies ranging from 100 Ws to 900 Ws). After ablation, the tissue was imaged with a swept source OCT system (at a wavelength of 1300 nm). Subsequently, the ablation lesions underwent the histological analysis. The ablation lesions could be visualized by OCT in all 17 samples with ablation powers ≥20 W, meanwhile, no lesion could be observed in the other eight samples with lower power (10 W). Lesion depths and lesion radiuses, as assessed by OCT, correlated well with those observed on the subsequent histological analysis (Spearman's r = 0.94, P < 0.001 and r = 0.84, P < 0.001). In addition, successful three-dimensional reconstructions of ablation lesions were performed. CONCLUSION: OCT can provide a visual high-resolution assessment of ablation lesions.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: