Why the study?
The success of radiofrequency ablation is limited by challenges in achieving durable, transmural lesions while avoiding complications such as incomplete ablation or over-ablation.
Can optical coherence tomography (OCT) accurately quantify lesion formation from radiofrequency ablation in human left atrial tissue?
Can optical coherence tomography (OCT) accurately quantify lesion formation from radiofrequency ablation in human left atrial tissue?
Optical coherence tomography can effectively quantify radiofrequency ablation lesion characteristics in human left atrial tissue, highlighting its potential for real-time monitoring during atrial fibrillation ablation.
Answers are grounded in this paper and cite their sources.
Ex vivo OCT assessment of RF lesions in human atrium is feasible; leaves open whether real-time guidance improves clinical outcomes.
Despite its widespread adoption, the success of radiofrequency (RF) ablation is often limited by challenges in achieving durable, transmural lesions while avoiding complications such as incomplete ablation or over-ablation. Optical coherence tomography (OCT) offers high-resolution visualization of cardiac tissue, enabling real-time assessment of lesion depth. Therefore, we investigated the impact of RF ablation on donated human left atrial tissue using an OCT imaging system to assess lesion formation in a controlled laboratory setting. RF ablation lesions were created at durations of 20, 40, 60, 80, and 100 seconds (s), and their effects were quantified by calculating the attenuation coefficient from OCT images. To identify tissue regions in the image, a U-Net model was employed for segmentation, achieving a mean intersection over union (IoU) of 0.9748 with an inference time of 82 milliseconds. Our results demonstrated clear differences in tissue response before and after ablation, with distinct lesion characteristics across the tested durations. One-way ANOVA analysis yielded a p-value of 1.09 × 10 −8 , confirming statistically significant differences among the ablation durations. These findings highlight the potential of SD-OCT for precise, real-time monitoring of ablation effects. Future work aims to integrate OCT with ablation catheters for clinical applications, enhancing the precision of catheter-based treatments for conditions like atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Mercyshalinie et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: