Key result
PRAM accurately measured cardiac output during stability, tachycardia, and vasoconstriction, but disagreed with thermodilution and TEE when volemia was reduced by >35%.
Why the study?
Does the Pressure-recording-analytical-method (PRAM) accurately measure cardiac output compared to thermodilution and transesophageal echocardiography during hemodynamic instability in a swine model?
Does the Pressure-recording-analytical-method (PRAM) accurately measure cardiac output compared to thermodilution and transesophageal echocardiography during hemodynamic instability in a swine model?
Answers are grounded in this paper and cite their sources.
PRAM provides accurate cardiac output measurements during various hemodynamic states but loses reliability during severe hypovolemia (>35% volume reduction).
Pulse contour methods (PCM) for the measurements of cardiac output (CO) are gaining popularity in intensive care settings but their reliability during hemodynamic instability has been questioned. Pressure-recording-analytical-method (PRAM) is a newly developed uncalibrated hemodynamic monitor and its capability in measuring CO during hemodynamic instability is still under investigation. Dobutamine (2.5 and 5 microg/kg/min), vasoconstriction (arginine-vasopressin 4, 8 and 16 IU/h), hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia), and volume resuscitation were induced in eight swine. CO by means of thermodilution (CO(ThD)), transesophageal echocardiography (CO(TEE)) and PRAM (CO(PRAM)) were contemporarily registered. R(2), bias, and percentage error were used to compare the methods. Comparison between CO(PRAM) and CO(ThD) resulted in: r(2)=0.87; bias=-0.006 l/min; precision=+/-0.87 l/min; percentage error=22.8%. Comparison between CO(PRAM) and CO(TEE) resulted in: r(2)=0.85; bias=-0.007 l/min; precision=+/-0.86 l/min; percentage error=22%. Sub-group analysis revealed disagreement between methods only during the last two steps of hemorrhage: CO(PRAM) vs. CO(ThD): r(2)=0.67, bias=-0.37 l/min, precision=+/-1.04 l/min, limits of agreement=-1.39+0.66 l/min, and percentage error=45%; CO(PRAM) vs. CO(TEE): r(2)=0.38, bias=0.4 l/min, precision=+/-1.42 l/min, limits of agreement=-0.99+1.79 l/min, and percentage error=62%. PRAM resulted to be accurate in measuring CO during hemodynamic stability, tachycardia, and vasoconstriction. When volemia was reduced by >35%, disagreement between methods was observed.
No takes yet. Share an insight, caveat, or question.
Romagnoli et al. (2009) studied Hemodynamic instability (n=8). Pressure-recording-analytical-method (PRAM) vs. Thermodilution and transesophageal echocardiography was evaluated on Cardiac output measurement agreement (R2, bias, percentage error) (r2=0.87 vs ThD; r2=0.85 vs TEE). PRAM accurately measured cardiac output during stability, tachycardia, and vasoconstriction, but disagreed with thermodilution and TEE when volemia was reduced by >35%.