Key result
Thrombotest yielded lower prothrombin times and occasionally grossly inaccurate results compared to the modified Quick test.
Why the study?
Does the Thrombotest provide comparable and accurate prothrombin time measurements compared to the modified Quick test in patients on anticoagulant therapy?
Observational (n=45)
Does the Thrombotest provide comparable and accurate prothrombin time measurements compared to the modified Quick test in patients on anticoagulant therapy?
The Thrombotest is less accurate and yields lower prothrombin times compared to the modified Quick test, making it inadequate for managing hypoprothrombinemia.
Answers are grounded in this paper and cite their sources.
Thrombotest may be unsuitable for reliable anticoagulation monitoring; leaves open standardization of prothrombin time assays.
Forty-five patients, given anticoagulant therapy with prothrombinopenic drugs, were given 10 mg. of phytonadione intravenously. Thrombotest prothrombin times and modified Quick-test prothrombin times were compared as indices for measuring the resulting increase in prothrombin times. These increases were similar generally for both tests. The thrombotest times were lower, approximately 0.5 to 0.67 of the comparable Quick-test times, and on several occasions, grossly inaccurate results were found with the thrombotest. Blood samples stored for 24 hours in Lusteroid tubes lost a significant reproducibility of thrombotest time. Therapeutic thrombotest-time levels are inadequate for acceptable hypoprothrombinemia as judged by the Quick-test times.
No takes yet. Share an insight, caveat, or question.
Shoshkes et al. (1963) conducted an observational in Anticoagulant therapy with prothrombinopenic drugs (n=45). Thrombotest vs. Modified Quick Test was evaluated on Increase in prothrombin times. Thrombotest yielded lower prothrombin times and occasionally grossly inaccurate results compared to the modified Quick test.
Synapse has enriched 10 related papers. Consider them for comparative context: