Key result
The EMIT 2000 digoxin assay demonstrated satisfactory precision and accuracy, a sensitivity of < 0.1 microgram/L, and very low DLIS interference compared to FPIA and RIA.
Why the study?
Does the EMIT 2000 digoxin assay provide accurate and precise measurements with low interference compared to FPIA and RIA?
Observational
Yes
Does the EMIT 2000 digoxin assay provide accurate and precise measurements with low interference compared to FPIA and RIA?
The EMIT 2000 digoxin assay is a precise, accurate, and sensitive method for therapeutic drug monitoring with minimal interference from digoxin-like immunoreactive substances.
Answers are grounded in this paper and cite their sources.
EMIT 2000 may aid precise digoxin TDM with minimal DLIS interference; leaves open larger validation studies before routine adoption.
Digoxin assays in plasma from patients treated with the drug have played an integral role in its therapeutic management. Commercial digoxin immunoassays have been criticized for poor performance owing to various interferences and limited sensitivity. The present study compared the performance of a new enzyme-multiplied immunoassay technique (EMIT 2000) to fluorescence polarization immunoassay (FPIA) and radioimmunoassay (RIA) in two separate Australian centers. Comparisons were made using standard indices of precision and accuracy, samples taken from patients, quality-assurance samples, and cord blood samples from neonates, in which high concentrations of digoxin-like immunoreactive substances (DLIS) would be anticipated. The results confirmed satisfactory precision and accuracy for therapeutic drug monitoring purposes, a sensitivity of < 0.1 microgram/L, and very low DLIS interference, as assessed by assay of neonatal cord blood samples.
No takes yet. Share an insight, caveat, or question.
Saccoia et al. (1996) conducted an observational in Patients treated with digoxin. EMIT 2000 digoxin assay vs. Fluorescence polarization immunoassay (FPIA) and radioimmunoassay (RIA) was evaluated on Precision, accuracy, sensitivity, and DLIS interference. The EMIT 2000 digoxin assay demonstrated satisfactory precision and accuracy, a sensitivity of < 0.1 microgram/L, and very low DLIS interference compared to FPIA and RIA.