Key result
The ratio of left subclavian artery to aortic isthmus was higher in fetuses with aortic coarctation than in normal fetuses, with a ratio ≥0.8 indicating diagnostic significance.
Why the study?
Does the fetal echocardiographic ratio of left subclavian artery to aortic isthmus (LSA/AoIS) accurately predict postnatal aortic coarctation?
Case-Control
Does the fetal echocardiographic ratio of left subclavian artery to aortic isthmus (LSA/AoIS) accurately predict postnatal aortic coarctation?
A fetal echocardiographic LSA/AoIS ratio ≥0.8 is a useful indirect diagnostic parameter for predicting postnatal aortic coarctation.
Answers are grounded in this paper and cite their sources.
LSA/AoIS ratio ≥0.8 may aid fetal coarctation prediction; leaves open prospective validation before clinical adoption.
Objective To evaluate the diagnostic value of the diameter ratio of left subclavian artery to aortic isthmus (LSA/AoIS) in fetuses with aortic coarctation (COA). Methods A retrospective study of 79 fetal echocardiographic data was undergone on 49 COA fetuses. The COA cases were divided into four groups according to different gestational week (cases in each group including follow-up review of different gestational weeks): group 1, 24-27+ 6 W; group 2, 28-31+ 6 W; group 3, 32-35+ 6 W; group 4, 36-39+ 6 W. The normal fetuses with gestational age matched were also divided into four control groups. The diameter of left subclavian artery (LSA) and aortic isthmus (AoIS) were measured, the ratio of LSA/AoIS of each group were calculated, and the data between the COA and control groups were compared. ROC curve analysis was used for LSA/AoIS to predict the demarcation point of postnatal COA. Results ①There was no statistic difference in the LSA diameter between COA groups and control groups (P>0.05): group 1 (1.87±0.42)mm vs (1.75±0.25)mm; group 2 (2.25±0.36)mm vs (2.21±0.22)mm; group 3 (2.74±0.32)mm vs (2.90±0.29)mm; group 4 (2.83±0.28)mm vs (3.06±0.30)mm; ②The ratio of LSA/AoIS was significantly increased in COA groups than those in control groups: group 1 (0.88±0.15) vs (0.66±0.06), group 2 (0.85±0.13) vs (0.64±0.05), group 3 (0.94±0.17) vs (0.73±0.07), group 4 (0.94±0.18) vs (0.70±0.07), the difference was statistically significant (P<0.05); ③The cut-off value of LSA/AoIS ratio were 0.78, 0.73, 0.83, 0.78 in each group, respectively. Conclusions The ratio of LSA/AoIS can be used as a useful echocardiographic parameter which suggest the presence of aortic coarctation. This ratio≥0.8 may have a certain diagnostic significance.
No takes yet. Share an insight, caveat, or question.
Xiaowei Liu (2017) conducted a case-control in Aortic coarctation (COA). Ratio of left subclavian artery to aortic isthmus (LSA/AoIS) vs. Normal fetuses was evaluated on LSA/AoIS ratio for predicting postnatal COA (p=<0.05). The ratio of left subclavian artery to aortic isthmus was higher in fetuses with aortic coarctation than in normal fetuses, with a ratio ≥0.8 indicating diagnostic significance.
Synapse has enriched 10 related papers. Consider them for comparative context: