Key result
In canine embolic pulmonary hypertension, pulmonary arterial pressure/cardiac output characteristics were unaffected by embolus size up to 1,000 microns.
Why the study?
Does embolus size affect pulmonary hemodynamics and gas exchange in a canine model of embolic pulmonary hypertension?
Does embolus size affect pulmonary hemodynamics and gas exchange in a canine model of embolic pulmonary hypertension?
In a canine model of embolic pulmonary hypertension, embolus size up to 1,000 microns does not affect pulmonary hemodynamics but does differentially impact gas exchange.
Answers are grounded in this paper and cite their sources.
Embolus size may not dictate hemodynamic response in this range; leaves open differential gas exchange effects and clinical translation.
We examined the effects of different-sized glass-bead embolization on pulmonary hemodynamics and gas exchange in 12 intact anesthetized dogs. Pulmonary hemodynamics were evaluated by multipoint pulmonary arterial pressure (Ppa)/cardiac output (Q) plots before and 60 min after sufficient amounts of 100-microns (n = 6 dogs) or 1,000-microns (n = 6 dogs) glass beads to triple baseline Ppa were given and again 20 min after 5 mg/kg hydralazine in all the animals. Gas exchange was assessed using the multiple inert gas elimination technique in each of these experimental conditions. Embolization increased both the extrapolated pressure intercepts (by 6 mmHg) and the slopes (by 5 mmHg.l-1.min.m2) of the linear Ppa/Q plots, together with an 80% angiographic pulmonary vascular obstruction. These changes were not significantly different in the two subgroups of dogs. However, arterial PO2 was most decreased after the 100-microns beads, and arterial PCO2 was most increased after the 1,000-microns beads. Both bead sizes deteriorated the distribution of ventilation (VA)/perfusion (Q) ratios, with development of lung units with higher as well as with lower than normal VA/Q. Only 100-microns beads generated a shunt. Only 1,000-microns beads generated a high VA/Q mode and increased inert gas dead space. Hydralazine increased the shunt and decreased the slope of the Ppa/Q plots after 100-microns beads and had no effect after 1,000-microns beads. We conclude that in embolic pulmonary hypertension, Ppa/Q characteristics are unaffected by embolus size up to 1,000 microns.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Delcroix et al. (1990) studied embolic pulmonary hypertension (n=12). 100-microns glass beads vs. 1,000-microns glass beads was evaluated on pulmonary hemodynamics (Ppa/Q plots). In canine embolic pulmonary hypertension, pulmonary arterial pressure/cardiac output characteristics were unaffected by embolus size up to 1,000 microns.
Synapse has enriched 10 related papers. Consider them for comparative context: