Key result
Acute pulmonary embolization during critical right coronary artery stenosis in dogs caused a 60% decline in coronary blood flow and severe myocardial dysfunction, which reversed upon release of the constriction.
Why the study?
Does acute pulmonary embolization affect right ventricular performance and coronary hemodynamics in a canine model with right coronary artery stenosis?
Does acute pulmonary embolization affect right ventricular performance and coronary hemodynamics in a canine model with right coronary artery stenosis?
Right ventricular function deteriorates in response to increased afterload when coronary vascular reserve is absent and aortic pressure decreases.
Answers are grounded in this paper and cite their sources.
RV dysfunction during acute PE with critical RCA stenosis may reflect lost coronary reserve; hypothesis-generating in this model and leaves open human relevance.
This study was performed to study the effects of acute pulmonary embolization (injection of autologous muscle) on global and regional (ultrasonic dimension technique) right ventricular (RV) performance, coronary hemodynamics (electromagnetic flow probes), and gas exchange during underlying critical stenosis (cuff occluder) of the right coronary artery (RCA) in eight open-chest dogs. Resting coronary blood flow (CBF) and regional myocardial performance remained unaffected by the induction of RCA stenosis. Following embolization pulmonary artery (PA) pressure, pulmonary vascular resistance, end-diastolic dimensions and pressure increased, and PA flow, stroke volume (SV), and aortic pressure (AoP) decreased (P less than 0.05). There was a marked decline (60%) in CBF accompanied by severe myocardial dysfunction suggestive of ischemia (akinesis, systolic lengthening, postsystolic shortening) in the area supplied by the stenosed RCA. Gas exchange, lung compliance, and pH worsened. Release of the RCA constriction led to a fourfold increase in CBF, return of PA flow, SV, and AoP to baseline values, and disappearance of regional myocardial dysfunction despite continued pulmonary hypertension. These data indicate that RV function may deteriorate in response to even small increases in afterload if coronary vascular reserve is absent and aortic pressure is allowed to decrease.
No takes yet. Share an insight, caveat, or question.
Hans‐Joachim Priebe (1990) studied Pulmonary hypertension and right coronary artery stenosis (canine model) (n=8). Acute pulmonary embolization during critical right coronary artery stenosis vs. Baseline / Release of RCA constriction was evaluated on Right ventricular performance, coronary hemodynamics, and gas exchange (p=<0.05). Acute pulmonary embolization during critical right coronary artery stenosis in dogs caused a 60% decline in coronary blood flow and severe myocardial dysfunction, which reversed upon release of the constriction.
Synapse has enriched 10 related papers. Consider them for comparative context: