Key result
MRI flow mapping accurately measured maximum blood flow velocity in the common carotid artery, demonstrating a significant correlation with conventional ultrasonic Doppler.
Why the study?
Does MRI flow mapping accurately measure blood flow velocity in the common carotid artery compared to ultrasonic Doppler in patients without cardiovascular risk factors?
Cross-Sectional (n=58)
No
Does MRI flow mapping accurately measure blood flow velocity in the common carotid artery compared to ultrasonic Doppler in patients without cardiovascular risk factors?
MRI flow mapping provides maximum blood flow velocity measurements in the common carotid artery that are in good agreement with conventional ultrasonic Doppler.
Answers are grounded in this paper and cite their sources.
Supports MRI carotid velocity assessment in low-risk adults; leaves open validation in patients with vascular disease.
Recently, it has become possible to measure blood flow velocity by MRI flow mapping. This study was designed to evaluate the accuracy of MRI flow mapping for measuring blood flow velocity in the common carotid artery (CCA), in comparison with a conventional ultrasonic quantitative flow measurement system (QFM) .We studied 58 patients aged 19-74 years (mean age, 40 years; 20 males, 38 females) without cerebrovascular disorders, essential hypertension, diabetes mellitus, or hyperlipidemia. The maximum and mean blood flow velocity of the CCA were determined by QFM 2000 XA (Nippon Koden Co.) and MRI (Siemens Co. 1.0T) based on MRI phase-contrast measurement. Technical parameters of MRI were: TR/TE/FA=31 ms/6 ms/25, slice=6 mm, matrix=256 × 256, field of view = 200 × 200 mm.The maximum blood flow velocity was 55.2 ± 16.8 cm/s by QFM, and 56.8 ± 15.5 cm/s by MRI. The maximum flow velocity in the CCA determined by MRI was significantly correlated with that determined by QFM (r=0.69, p<0.001), and the two methods were in good agreement. The mean flow velocity in the CCA was 22.6±5.6cm/s by QFM, and 25.3±7.3 cm/s by MRI. The mean flow velocity measured by MRI was higher than that measured by QFM, but the two values were significantly correlated (r=0.59, p<0.001) .These results indicate that the maximum blood flow velocity in the CCA as measured by MRI is in good agreement with that determined by QFM.
No takes yet. Share an insight, caveat, or question.
Nomura et al. (1999) conducted a cross-sectional in Healthy subjects (n=58). MRI flow mapping vs. Ultrasonic quantitative flow measurement system (QFM) was evaluated on Maximum blood flow velocity in the common carotid artery (r=0.69, p=<0.001). MRI flow mapping accurately measured maximum blood flow velocity in the common carotid artery, demonstrating a significant correlation with conventional ultrasonic Doppler.