Key result
Intravenous digoxin administration in a patient with sick sinus syndrome caused severe sinus node dysfunction, including sinus pauses exceeding six seconds after overdrive pacing.
Why the study?
Does digoxin worsen sinus node function in patients with sick sinus syndrome?
Case Report (n=1)
Does digoxin worsen sinus node function in patients with sick sinus syndrome?
Digoxin can provoke severe sinus node dysfunction and prolonged sinus pauses in patients with sick sinus syndrome, suggesting caution when using digitalis in this population.
Answers are grounded in this paper and cite their sources.
May support caution with digoxin in sick sinus syndrome; hypothesis-generating case report requiring prospective validation.
Digoxin, in a common clinical dose and at a low serum level, brought out severe manifestations of sinus node dysfunction in a patient who had previously undergone successful mitral valve replacement. This report presents the results of extensive clinical and electrophysiologic studies of this patient before and after a digoxin challenge. In the absence of cardiac glycoside, the only demonstrable abnormalities of sinus node function were mild resting sinus bradycardia and failure to respond to atropine administration. Responses to isoproterenol administration, programmed premature atrial stimulation, and overdrive pacing at several cycle lengths were normal. Following the administration of intravenous digoxin, 1.025 mg/24 hrs, the resting sinus cycle length increased and the response to overdrive pacing became markedly abnormal. The latter was followed by sinus pauses in excess of six seconds, even at relatively slow overdrive pacing rates. The electrophysiologic and clinical implications of these data are discussed. It is suggested that despite previous reports that digitalis preparations are relatively well tolerated by patients with sick sinus syndrome, caution should be used when administering these drugs to this group of patients.
No takes yet. Share an insight, caveat, or question.
Margolis et al. (1975) conducted a case report in Sick sinus syndrome (n=1). Digoxin vs. Baseline (absence of cardiac glycoside) was evaluated on Sinus node function (clinical and electrophysiologic response). Intravenous digoxin administration in a patient with sick sinus syndrome caused severe sinus node dysfunction, including sinus pauses exceeding six seconds after overdrive pacing.