Key result
The stent eversion method using subcutaneous implantation for 4 weeks successfully produced robust, completely autologous stent-biovalves with adequate valve function in all cases.
Why the study?
Does the stent eversion method allow for the successful construction of an autologous stent-biovalve in animal models?
Does the stent eversion method allow for the successful construction of an autologous stent-biovalve in animal models?
The stent eversion method is a highly effective novel technique for constructing a robust, completely autologous stent-biovalve with adequate valve function.
Answers are grounded in this paper and cite their sources.
Supports autologous biovalve development in animals; leaves open clinical translation pending human studies.
We designed a novel method for constructing an autologous heart valve with a stent, called a stent-biovalve. In constructing completely autologous heart valves, named biovalves, which used in-body tissue architecture technology, tissues for leaflets were formed via ingrowths into narrow apertures in the preparation molds, frequently leading to delayed or incomplete biovalve preparation. In this technique, self-expandable nitinol stents after everting were mounted on an acrylic column-shaped part and partially covered with an acrylic cylinder-shaped part with three slits. This assembled mold was placed into subcutaneous abdominal pouches in beagles or goats for 4 weeks. Upon removing the acrylic parts after harvesting and trimming of capsulated tissues, a tubular hollow structure with three pocket-flaps of membranous tissue rigidly fixed to the stent's outer surface was obtained. Then, the stent was turned inside out to the original form, thus moving the pocket-flaps from outside to the inside. Stent-biovalves with a sufficient coaptation area were thus obtained with little tissue damage in all cases. The valve opened smoothly, and high aperture ratio was noted. This novel technique was thus highly effective in constructing a robust, completely autologous stent-biovalve with adequate valve function.
No takes yet. Share an insight, caveat, or question.
Mizuno et al. (2013) studied this question. Stent eversion method for autologous heart valve construction was evaluated on Successful construction of a robust stent-biovalve with adequate valve function. The stent eversion method using subcutaneous implantation for 4 weeks successfully produced robust, completely autologous stent-biovalves with adequate valve function in all cases.
Synapse has enriched 10 related papers. Consider them for comparative context: