Key result
The FLU OIA test had a lower positivity rate compared to cell culture and RT-PCR for detecting influenza A virus from throat swab specimens.
Why the study?
Does the FLU OIA test accurately detect influenza viruses compared to cell culture and RT-PCR in subjects with flu-like illness?
Cross-Sectional (n=146)
Yes
Does the FLU OIA test accurately detect influenza viruses compared to cell culture and RT-PCR in subjects with flu-like illness?
The FLU OIA test has a significantly lower positivity rate for detecting influenza A compared to cell culture and RT-PCR.
Answers are grounded in this paper and cite their sources.
Caution against sole reliance on FLU OIA for influenza A; leaves open its diagnostic role versus culture or RT-PCR.
The FLU OIA test was evaluated with 146 throat swab specimens from subjects with a flu-like illness in six Canadian clinics during the 1999-2000 flu season. The rate of positivity of the FLU OIA test (41.5%) was significantly lower than that of cell culture (55.2%) or reverse transcription-PCR (55.9%) during a season in which only influenza A virus was detected.
No takes yet. Share an insight, caveat, or question.
Boivin et al. (2001) conducted a cross-sectional in Flu-like illness (n=146). FLU OIA test vs. Cell culture and RT-PCR was evaluated on Rate of positivity for influenza detection (p=0.009). The FLU OIA test had a lower positivity rate compared to cell culture and RT-PCR for detecting influenza A virus from throat swab specimens.