Key result
CRT-D Futility score outperforms existing models in predicting 1-year mortality, achieving ~0.69 AUC.
Why the study?
The risk-benefit balance of CRT-D over CRT pacemaker remains debated, motivating the development of a clinical score to identify patients at risk of poor 1-year outcome after CRT-D implantation.
Does the CRT-D Futility score accurately predict 1-year all-cause mortality (futility) compared with the Goldenberg and EAARN scores in patients undergoing prophylactic CRT-D implantation?
Cohort (n=23,029)
Yes
Does the CRT-D Futility score accurately predict 1-year all-cause mortality (futility) compared with the Goldenberg and EAARN scores in patients undergoing prophylactic CRT-D implantation?
The CRT-D Futility score provides a calibrated, objective clinical tool that outperforms existing risk scores in identifying patients at high risk of 1-year mortality after prophylactic CRT-D implantation to guide shared decision-making between CRT-D and CRT-P.
Answers are grounded in this paper and cite their sources.
May aid shared decision-making for prophylactic CRT-D; extends prior scores yet leaves open impact on outcomes.
BACKGROUND: Risk-benefit for cardiac resynchronisation therapy (CRT) defibrillator (CRT-D) over CRT pacemaker remains a matter of debate. We aimed to identify patients with a poor outcome within 1 year of CRT-D implantation, and to develop a CRT-D Futility score. METHODS: Based on an administrative hospital-discharge database, all consecutive patients treated with prophylactic CRT-D implantation in France (2010-2019) were included. A prediction model was derived and validated for 1-year all-cause death after CRT-D implantation (considered as futility) by using split-sample validation. RESULTS: Among 23 029 patients (mean age 68±10 years; 4873 (21.2%) women), 7016 deaths were recorded (yearly incidence rate 7.2%), of which 1604 (22.8%) occurred within 1 year of CRT-D implantation. In the derivation cohort (n=11 514), the final logistic regression model included-as main predictors of futility-older age, diabetes, mitral regurgitation, aortic stenosis, history of hospitalisation with heart failure, history of pulmonary oedema, atrial fibrillation, renal disease, liver disease, undernutrition and anaemia. Area under the curve for the CRT-D Futility score was 0.716 (95% CI: 0.698 to 0.734) in the derivation cohort and 0.692 (0.673 to 0.710) in the validation cohort. The Hosmer-Lemeshow test had a p-value of 0.57 suggesting accurate calibration. The CRT-D Futility score outperformed the Goldenberg and EAARN scores for identifying futility. Based on the CRT-D Futility score, 15.9% of these patients were categorised at high risk (predicted futility of 16.6%). CONCLUSIONS: The CRT-D Futility score, established from a large nationwide cohort of patients treated with CRT-D, may be a relevant tool for optimising healthcare decision-making.
No takes yet. Share an insight, caveat, or question.
Maille et al. (2022) conducted a cohort in Heart failure treated with prophylactic cardiac resynchronisation therapy defibrillator (CRT-D) implantation (n=23,029). CRT-D Futility score vs. Goldenberg score and EAARN score was evaluated on 1-year all-cause death after CRT-D implantation (CRT-D futility) (AUC 0.692 (validation cohort); AUC 0.716 (derivation cohort), 95% CI 0.673-0.710, p=<0.0001). The CRT-D Futility score predicted 1-year all-cause mortality after prophylactic CRT-D implantation with an AUC of 0.692 in the validation cohort, outperforming Goldenberg and EAARN scores.
Synapse has enriched 10 related papers. Consider them for comparative context: